Gardner Denver ELECTRA-SAVER II Service Manual page 31

Stationary base mounted compressor
Hide thumbs Also See for ELECTRA-SAVER II:

Advertisement

t'~,,
_
"B'
NOTES
FOR
WIRING
DIAGRAMS
(Figures
13-4
thru 17-4)
ALL NOTES
ARE
NOT
APPLICABLE
TO ALL
WIRING
DIAGRAMS
READ
CAREFULLY
AND
COMPLETELY
FOR
WIRING
INSTRUCTIONS.
All equipment
must be connected
and phased
exactly
as shown
All
Piping
wiring
and other equipment
not specified
on order
is to be supplied
by other than Gardner-Denver
Compressors.
Compressor
power suPPly disconnecting
means–
Fused
Switch
or Circuit
Breaker
(not furnished
as
a standard
item — if orderedj
it must be remote
mounted
and wired
by customer).
EauiDment
must be arounded
in accordance
with
Table
250-95
of the-National
Electrical
Coda
~WARNING
"c'
"1)"
An equipment ground jumper equal in size to the equip
ment ground conductor
must be used to connect the
compressor motor base to main base because the bases
are isolated from each other by vibration
mounts.
The
oil cooler
motor (when
used)
is grounded
to
the starter
as shown
The
ground
conductor
for
this motor
is compatible
to the motor short circuit
protection
When
the control
circuit
voltage
is from a separate
power (voltage)
source
and is not controlled
by the
motor
power
supply
disconnecting
means
a dis
connect
switch (DS)
interlock
(not furnished)
shall
be
mounted
immediately
adjacent
to the
motor
power
SUPPlY disconnecting
means
and wired
by
the customer
as shown
in the Schematic
Wiring
Diagram
and per the data
shown
for that starter
and
its disconnecting
means
This interlocking
device
(DS)
may be an Auxiliary
(Aux)
or Electrical
Interlock
( E l.) contact
operated
by the handle
of the motor
power
supPly
discon
netting
means
When
this
disconnect
switch
(DS)
interlock
is a
separate
device
it shall
be used to turn the con
trol
circuit
"OFF'
before
operating
the
motor
power
SUPPlY disconnecting
means
See
Article
430-74
of the
National
Electrical
Coda
The compressor
motor
starter
is remote
mounted
and wired
by the customer.
All reduced
voltage
(current
inrush) starters
mart
ual and
magnetic
are
also
remote
mounted
and
wired
by the
customer.
See
reduced
voltage
starter
note
on page
20.
The compressor
motor starter
coil voltage
shall be
the same
as the motor voltage
i.e. 200,
230,
460
volts
etc,
unless the starter
is ordered
with its own
fused
control
transformer.
The contact
(relay
or
fan-oil
cooler
starter
interlock)
from the compres
sor control
panel
to the
remote
mounted
starter
control
circuit
is rated
600
volts
" "D1"
Remote
mounted
magnetic
compressor
starter
control
circuits
are to be connected
for TWO (2)
WIRE
control
The remote
compressor
starter
control
wiring shall
be interlocked
with the rest of the control
wiring as
shown
in the Schematic
Wiring
Diagram
and per
the wiring
data shown for the remote
starter.
The
internal
wiring
shown
is typical
only.
For exact
wiring
see diagram
on inside of starter
or diagram
supplied
with
starter.
Motor control
circuits
must be fused
in accordance
with article
430-72
of the National
Electrical
Code
Control
circuits
shall have short circuit
protection
(fuses
etc)
in all instances
because
the control
circuit
wiring
leaves
the starter
enclosure
to go to
the external
devices
An ESG66459
Electrical
Group
with Buss Limitron
KTK15
(600V-15Q
Fuses will be furnished
in addi
tion to starter
control
fuses for water-cooled
com
pressers
with
remote
mounted
manual
reduced
voltage
starters
Customer
is to mount
and
wire
fuses
using
the
following
m-ounting
data
Fuse
Block
Mounting
" D2° –
" E"
"E,
,,
_
Data
Approximate
area
2-1 /2"
L x 3" H
Mounting
centers
2.1"
no.
29
Drill
(.1360)
two
holes for No. 8 self-tapping
screws
furnished
with
fuse
block
and fuses
A G.E
CR234
air break
manual
starter
is shown
The undervoltage
(latch)
coil circuit
for the G.E
oil
break
and other
manufacturers'
manual
starters
is
to be
similarly
reconnected
and
interlocked
as
shown
with
the compressor
control
wiring.
Oil Cooler
power
supply
disconnecting
means
Fused Switch
or Circuit
Breaker.
NOT FURNISHED
— and is remote
mounted
and wired
by customer.
Wire and conduit
in the following
table
is sized for
SF.
T.EAO.
motors
when
used
This
table
may
also be used for T. EF. C. motors
or refer
to N.EC
for T. EF. C. motors
Fused
combination
starter
mounted
on separate
oil cooler
module
in NEMA
1 enclosure
unless
specified
NEMA
4
for outdoor
usage
The
oil
cooler
module
is remote
from the compressor
and
the interconnecting
wiring
is not furnished
This
interconnecting
wiring (by customerj
is to be inter-
locked
with the rest of the control
wiring
as shown
in the
Schematic
Wiring
Diagram
and
per
the
wiring
data
shown
for
oil
cooler
starter.
The
remote
oil cooler
equipment
ground
wire
must be
13-9-630
Section
4
Page
15