Safety
Valve
(Figures
2-1 & 3-1) - A pressure
relief valve is
installed
in the
final
discharge
manifold
and
set
at the
factory
to approximately
120%
of the specified
operating
pressure
for
protection
against
overpressure.
Periodic
checks
should
be
made
to insure
its proper
operation
Never
operate
the unit without
a proper safety valve setting
Low
Demand
Mode
Pressure
Switch
(Figure
1-4) - The
low demand
mode
switch
when
turned
ON will cause
the
low demand
mode
pressure
switch
to reenergize
the low
demand
mode
solenoid
valve
when
discharge
pressure
reaches
the
set point
This switch
should
be set approx-
imately
5
PSI
above
full
load
pressure
with
a 8-12
PSI
differential
Low Demand
Mode
Unloader
Solenoid
(Figure
1-4) - The
low demand
mode solenoid
valve when energized
supplies
an
air
signal
to
close
the
blowdown
valve.
When
de
energized
it supplies
an air signal to close compressor
inlet
valve
and
exhausts
air to open
the
blowdown
valve
Pressure
Regulator
(Figure
1 -4) - The pressure
regulator
must
be set 25-30
PSIG
to prevent
inlet
valve "slam".
Reservoir
Pressure
Switch
(Figure
1 -4) - A pressure
switch
is connected
to the discharge
manifold
and wired
to the
motor
control
circuit
to prevent
attempted
starting
of the
unit when
there
is more
than
5 PSIG
pressure
in the oil
reservoir.
This protects
the unit from starting
against
load
when
the
oil reservoir
has not had enough
time
to blow
down
Blowdown
time
is usually
about
45
seconds
, WARNING
Do not set the switch higher than 5 PSIG or render the
switch
inoperative
severe damage
to the motor can
occur if started
with pressure
in the oil reservoir
Low
Oil
Pressure
Shutdown
(Figure
1 -4)
-
Units
are
provided
with a pressure
switch
piped to the compressor
oil
sump and wired
into the motor control
circuit
to protect
the
unit against
operation
at too low an oil pressure
and against
complete
lubrication
failure
due to an oil line restriction
or
sudden
loss of oil pressure.
The pressure
switch
is set 10-
15 PSIG and will stop the unit if the oil pressure
falls below
this pressure
any time
during
operation,
and will prevent
the unit being started
if the oil pressure
does not rise to 10-
15
PSIG
within
10
seconds
of starting.
The pressure
switch
is set at 10-15
PSIG
a the factory.
If
resetting
is necessary
HIGH
DISCHARGE
TEMPERATURE
SWITCH
CONDITION
CHART
"A
indicates
Temperature
Condition
at Compressor
Discharge.
"B' indicates
Temperature
Condition
at Oil Separator.
"C
indicates
Probe
Condition.
o
POWER
"A"
o
"c
o
0 \
"B
o
CONDITION
POWER
ON
"A
"B'
"c"
POWER
OFF
OFF
OFF
OFF
OFF
NORMAL
TEMPERATURE
RED
RED
RED
OFF
COMPRESSOR
HIGH
TEMPERATURE
RED
OFF
RED
OFF
SEPARATOR
HIGH
TEMPERATURE
RED
RED
OFF
OFF
COMPRESSOR
PROBE
OPEN
RED
OFF
RED
GREEN
SEPARATOR
PROBE
OPEN
RED
RED
OFF
GREEN
COMPRESSOR
PROBE
SHORTED
RED
OFF
RED
RED
SEPARATOR
PROBE
SHORTED
RED
RED
OFF
RED
COMPRESSOR
PROBE
SHORTED/
separator
PROBE
OPEN
RED
OFF
OFF
ORANGE
COMPRESSOR
PROBE
OPEN/
SEPARATOR
PROBE
SHORTED
RED
OFF
OFF
ORANGE
FIGURE
2-4
13-9-630
Section
4
Page
3

Advertisement

loading

This manual is also suitable for:

EcqqnEcqsnEcqqoEcqso