For
water cooled
oil systems,
the water
flows at various
temperatures
outlined
in Section
2 will hold the discharge
temperature
below
the 80°
F. ambient
temperature
level
of Figure
10-5.
Small
variations
in specific
water
flows or
temperatures
will not be noted
in the discharge
temper-
ature
since
the
water
control
valve
will
tend
to hold
a
constant
oil temperature
A significant
change
in the dis
charge
temperature
is cause
to check
for a change
in water
flow or temperature
Oil Inlet
Pressura
Check
at the fitting
in the line near
the compressor
oil inlet
With air receiver
pressure
at 100
PSI, oil inlet
pressure
should
match
values
shown
in the
following
table.
Size
Pressure
125&150
HP
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70-80
Oil Cooler
Pressure
Differential
(Air-Cooled
Radiator
— 2
to25
PSI (65 to 150
PSIG Receiver
Pressure)
Check
at the fitting
in the inlet and outlet
lines of the oil cooler.
Oil
Cooler
Oil
Pressure
Differential
(Watercooled
Heat Exchanger
— 2 to 25
PSI (65 to 150
PSIG
Receiver
Pressure)
— Check
at the heat exchanger
oil inlet and out-
let fittings
Oil Cooler
Temperature
Differential
(Air-Cooled
Ra
diaton
The
oil
temperature
differential
depends
on
the temperature
of the air at the oil cooler
fan and clean
Iiness of the core faces
As ambient
temperatures
and core
restrictions
increase
the oil cooler
outlet
temperature
will
increase
The
inlet
oil temperature
may
be checked
at
the fittings
in the
oil inlet
line on the oil cooler
module
The outlet
oil temperatures
may be checked
at the fittings
in the
oil inlet
line
on the oil cooler
module
The outlet
oil temperatures
may be checked
at the fitting
in the oil
outlet
line.
Oil Cooler Temperature
Differential
(Watercooled
Heat
Exchanger)
The oil temperature
differential
depends
on
the
inlet
water
temperature
and
the
water
flow
rate
permitted
by the water
flow control
valve
setting
The oil
inlet temperature
is approximately
the same
as the air dis
charge
temperature—
see gauge
on instrument
panel
The
oil outlet
temperature
may be checked
at the compressor
oil inlet
line fitting
Oil Cooler
Water
Pressure
Differential
(Watercooled
Heat
Exchanger)
The
water
pressure
differential
through
the
heat
exchanger
will depend
on suPPly
pres
sure
flow rate
cooler
tube cleanliness
and outlet
pressure
The
inlet
and
outlet
water
pressures
may
be checked
at
pipe
fittings
supplied
by the customer.