1.
2.
Adjust
the upper
limit pressure
to 15 PSIG
by turning
the slotted
screw (pressure)
near the top of the switch
Clockwise
movement
of the screw
raises the pressure
counterclockwise
lowers
the
pressure
Note
approx-
imate
pressure
setting
is indicated
on the range
scale
on left face
of switch
Adjust
the lower
limit pressure
to 10 PSIG
by turning
the slotted
screw (differential)
near the bottom
of the
switch
until the cam-shaped
calibrated
dial under
the
pressure
setting
screw
indicates
about 1/4 of full scale
reading
from
lowest
setting
Clockwise
movement
of
the screw
reduces
the
differential
counterclockwise
increaaes
differential
Note
differential
range
(1 -18
PSI)
is indicated
by marks
on the cam-shaped
dial
If a unit with Constant
Speed
with Low Demand
Mode
Switch
shuts down from low oil pressure
pressing
the
ON
button
will restart
the
unit
Since
the
Automatic
Start/Timed
Stop
control
is
an
automatic
starting
type
a reset
relay
is used as a positive
means
to interrupt
the circuit
o'n either
a low oil pressure
shutdown
or high discharge
air temperature
shut-down
to
restart
these
units
press the black bar marked
RESET
and
then
press
the ON
button
CAUTION
Do
not
continue
to restart
the unit
if the same
malfunction
occurs within a short period of time Find
and correct the trouble
before resuming operation
This
switch
should
be
checked
periodically
to
assure
proper
operation
To check
disconnect
the timed-opening
instantaneous
closing
time
delay
relay from the system
at
point 10 (see wiring diagram).
Try to start unit — unit should
not run — if it does
switch
is inoperative
and should
be
replaced
Be sure to reconnect
the time
delay
relay
after
checking
Low Oil Pressure
Time
Delay
Switch
(Figures
1-4 & 3-4)
located
in the
control
panel
enclosure
is wired
into the
control
circuit
to provide
the 10-second
delay
required
for
the
compressor
oil pressure
to rise
to 10-15
PSIG
and
energize
the
low oil pressure
switch
circuit
MANUAL OPERATOR TAB
1
~N.C. TIMING CONTACT
MOVEABLE INSTAN.
1
TANEOUS CONTACT
CARRIER -
DO NOT L
uSE AS A MANUAL
OPERATOR
I
TIME
SETTING
AOJUSTING XREW J
A75852
FIGURE
3-4
LOW
OIL
PRESSURE
TIME
DELAY
SWITCH
To check
the time
delay
switch
setting
1.
Pull main
breaker
switch
2.
Move
black
timer
tab located
on the left half of relay
block to the ON position
and hold
Timer
will begin
to
run for set time
the right half of the relay block
the contacts
will open
when
the
preset
time
runs out
4.
Adjustment
of time
delay
setting
is made
by turning
screw on lower right face of relay block to a faster(F)
or
slower (S) setting.
Recheck
setting
of relay as in No. 2
and 3 above
each
time
screw
is turned
, WARNING
Timer is factory set at 10 seconds
NEVER ATTEMPT
TO ADJUST
THE
TIMING
RELAY
FOR MORE
THAN 15 SECONDS
DELAY
— serious compressor
damage may result from operation without
lubrication
for even a short period
~CAUTION
INSTRUMENTS
& GAUGES
(Figures
3-1
& 1-4)
- Both
control
system
instrument
panels
incorporate
the following:
Hourmeter
- A continuous
reading
(nonreset)
type
hour-
meter
displays
the accumulated
operating
time of the unit
and provides
a convenient
means
for scheduling
changes
of oil supply
and servicing
of filters
separators
and other
devices
Air Pressure
Geuge
- A direct
reading
air pressure
gauge
indicates
the final discharge
air pressure
at the discharge
manifold
Discharge
Air
Temperature
Gauge
- A direct
reading
temperature
gauge
indicates
the compressor
discharge
air
temperature
Pressure
Differential
Gauge
- This
gauge
reads
the
pressure
differential
across
the oil separators
providing
a
continuous
monitoring
of their
condition
and
indicates
when
changing
of the
elements
is required
Air Filter
Indicator-
An air filter indicator
is located
on the
instrument
panel
and indicates
when
the air filter
requires
servicing
Oil Filter
Indicator-
An oil filter indicator
is located
on the
head
of the
oil filter
and
indicates
when
oil filter
needs
servicing
a-
ADJUSTING
SCREW
RETAINING
RING
~
SPRING
AIR
IN
B75121
w
/
\
3.
Observe
the action
of the right hand set of contacts
on
FIGURE
4-4
MINIMUM
DISCHARGE
PRESSURE
VALVE
13-9-630