Gardner Denver ELECTRA-SAVER II Service Manual page 33

Stationary base mounted compressor
Hide thumbs Also See for ELECTRA-SAVER II:

Advertisement

RD. V.
BOOT
C. R
D.S.A
D. S. C.
FUSE
H. D.T.S.
H. M.
l.c. 1.0.
1. C .T.O.
i.o. l.c.
1.0. T. C.
LO.P.S
M
— 1" —
2-Way
Normally
Open
— 2W. N.O. Air
Operated
Valve
90AR1
14.
B.D.V.'s
are sized
to blow down oil reservoir
in approximately
45
seconds
If the
com
pressor
is started
or loads
up (low unloaded
HP only) before
the reservoir
is blown down
the compressor
may be starting
under
load
which
may
cause
motor
failure
and/or
oil
mist will be carried
over
into the lines
— 24 CA281
Transparent
for
PB's
when
NEMA
4.
Control
Relay
24 CA771
110/120
V–
50/60
Hz Coil –
2S.P.N.O.
Convertible
600
Volt Contacts
— Disconnect
Switch
Interlock
— Aftercooler.
— Disconnect
Switch
Interlock
— Compressor.
— 2-1/4
AMP — 250
Volt — Time
Delay
Type.
Tan Terminal
Board –
24 CA158
(Buss
FRN
2-1 /2
or Equal).
Blue
Terminal
Board
24 CA1026
(Buss
MDL
2-1/2
or Equal).
— High
Discharge
Temperature
Switch
— Set
230°
F.
Single
Probe
Controller
24 CA779.
Ther-
mistor
Probe
24 CA780.
Dual Probe
Controller
— 21 D80.
Thermistor
Probe
— 21 D81
(2
Required).
— Terminals
on Temperature
Switch.
— Hourmeter
— 2009369
— 120
V — 60
Hz
(Alternate
2009370
110
V –
50
Hz).
— Instant
Closing
— Instant
Opening.
— Instant
Closing
— Timed
Opening.
— Instant
Opening
— Instant
Closing.
— Instant
Opening
— Timed
Closing.
Low Oil Pressure
Switch
88A31 O Set 10-
15
Psi.
NOTE
When starting
unit for first
time at final
in
stallation
loosen tube fitting
on bottom of pres-
sure switch
After compressor is started
and
oil appears at the fitting
tighten fitting
If
compressor shuts down on low oil pressure on
the first
start until
all the air has been
bled off thru the blowdown
valve before pressing
reset button
and restarting
the compressor.
Motor
Starter
Coil
Contacts
etc
The
oil
cooler
starter
furnished
as standard
equip
ment has 1 10/1 20 V— 50/60
Hz coils
(See
Note
"D" for Compressor
Starter.)
M. U.-B. D.V. — Magnetic
Unloader
Blowdown
Solenoid
Valve—
1 10/120
V— 50/60
Hz—
Four Way
91 B34.
The LOW DEMAND
MODE
switch
should
be
in the "OFF'
position
when
starting
the unit
to keep
the compressor
from cycling
rapidly
if service
valve
is closed
M. W. V.
Magnetic
Water
Valve–
11 0/120
V–
50/60
Hz –
Two Way
Normally
Closed
2W. N.C.
WATER-COOLED
OIL
COOLER
NEMA
1
NEMA
4
91 B3 –
1-1/2"
91 B24
1-1/2"
M. W.V.'S are also shown
on the Wiring
Dia-
grams
for Water-Cooled
Aftercoolers
(when
used) and are to be sized
for the aftercooler
(if used).
O. L
RP. S.
RR
T. C. 1.0.
T. D.
T. 0.1. C.
V. R.
\/
-o-
/ \
— Overload
— Heater
Contacts
— Reservoir
Pressure
Switch
(not standard
on
early
models)
88 H99.
Set 5 PSI falling
pressure
Prevents
compressor
starting
after
a power
shutdown
and/or
power
interruption
until
reservoir
is below
5 PSI.
Reset
Relay
24 CA541
1 10/120
V —
50/60
Hz Coil –
2S. P. N.O. Convertible
300
Volt Contacts
Used with all automatic
start
controls
which
have
low oil pressure
shut-
down
This relay gives LOW VOLTAGE
pro
TECTION
which
means
a manual
reset
is
required
after
every
power
turnoff
or inter-
ruption
See
the appropriate
control
wiring
diagram
for additional
control
switch
com
ponents
and
resetting
instructions
— Timed
Closing
— Instant
Opening.
Time Delay
Relay–
24 CA285
1 10/120
V
— 50/60
Hz Coil — is set for a maximum
of
10
seconds
to establish
oil pressure
after
each
start-up
If the TD timing
coil fails the
compressor
will not load when
started
and
will unload
if running
when
control
is cow
stant
speed
If the TD timing
relay
fails on
an
autostart
timed-stop
control
the
com-
pressor
will not start
if running
unit will un-
load and continue
running
unloaded
for the
time
setting
of TR
— Timed
Opening
— Instant
Closing.
— Voltage
Relay
200
Volts –
60
Hz –
24 CA772
230
Volts –
60
hz –
24 CA773
380/460
Volts –
50/60
hz –
24 CA774
575
Volts –
60
hz — 24 CA775
Jumpers
On Terminal
Blocks
(T. B)
— Indicating
Light
— 24CA40
(Sylvania
120
PSB
or Equal).
13-9-630
Section
4
Page
17

Advertisement

loading