Starter
— The main starter
is to be mounted
at a location
selected
by the
user at the time
of installation
The first
three
(3)
feet
of line from
the
motor
conduit
box to the
starter
must
be of flexible
conduit
to maintain
effective
vibration
isolation
Electrical
connections
to other
parts of
the unit (instrument
panel
fan motor, etc)
from the starter
do not require
flexible
conduit
since
the compressor
and
motor
are
already
isolated
from
these
parts
See
Table
110-16
(a)
National
Electrical
Code
for
correct
working
clearance
Grounding
— Equipment
must be grounded
in accordance
with
Table
250-95
of the
National
Electrical
Code.
AWARNING
An
equipment
ground jumper
equal in size to the
equipment ground conductor
must be used to connect
the compressor motor to the main base since they are
isolated from the base by vibration
mounts~
The oil
cooler fan motor frame will be grounded
to the main
base with a grounding
conductor compatible
with the
fan short circuit protection
at the factory.
MOTOR
LUBRICATION
Long
time
satisfactory
opera-
tion of an electric
motor
depends
in large
measure
on the
bearings
and timely
lubrication.
The following
charts
show
recommended
grease
qualities
and regressing
intervals
for
motor
supplied
with ball bearings
For additional
informa
tion
refer
to the
motor
manufacturers
instructions
The
following
procedure
should
be
used
in regressing
1.
2.
3.
4.
5.
6.
7.
Stop
the
unit
Disconnect
the
unit from
the
power
supply.
Remove
the relief
plug and free the hole of hardened
grease.
Wipe the lubrication
fitting clean
and add grease
with
a hand-operated
grease
gun.
Leave
the relief
plug temporarily
off.
Reconnect
the
unit and run for about 20
grease,
Stop
the
unit
Replace
Restart
the
unit
GREASE
RECOMMENDATIONS
.
Worked
Penetration
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Oil Viscosity,
SSU At lOOO
F.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Soap
Type
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
N-H Bomb
Minimum
Hours
For20
PSl
Drop
At210°
F. . . . . . . . . . . . . . . . . . . . . . . . .
Bleeding
Maximum
Weight%
ln500Hours
212"
F.
. . . . . . . . . . . . . . . . . . . . . . . . . . .
Rust
Inhibiting
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
REGRESSING
INTERVAL
minutes
to expell
the excess
the
relief
plug.
Standard
Service
265-296
400-550
Lithium
750
10
Yes
High
Temperature
220-240
475-525
Lithium
1000
3
Yes
Type
Of Service
Typical
Examples
Rating
Relubrication
Interval
150
HP and
Below
18
Months
Standard
One
Or two-shift
Operation
Over
150
HP
12
Months
150
HP and
Below
9 Months
Severe
Continuous
Operation
Over
150
HP
6 Months
150
HP and
Below
4 Months
Very
Severe
Dirty
Locations
High
Ambient
Temperature
Over
150
HP
2 Months
13-9-630
Section
2
Page
6