Parameter
LED Indicator
Phone Number
Management
Test Mode
Reduced Sensitivity
Mode
Cloud Service
Connection
Description
LED Indicator is enabled by default.
If LED Indicator is disabled, the LED indicator will remain off
regardless of whether the hub is functioning normally or not.
The function is only available when the version of the DMSS app is
1.96 or later, and the hub is V1.001.0000000.4.R.211014 or later.
Tap Add on the upper-right corner of the page to add a phone number
to receive the event, and then select the event type that needs to send
SMS. The event types include alarm, fault, operation, and whether the
alarm is linked to the phone.
After adding, you can swipe left to test phone calls and SMS messages to
verify whether the current phone number is valid. You can also swipe
left to delete the mobile phone number.
Tap the phone number to enter the phone number editing page, and
then you can edit the number and select the event type that needs to
send SMS.
Only 2G/4G devices support this function.
Tap Start to test the status of the peripherals connecting to the hub in
different areas, and then tap Stop to complete detection.
Enable Reduced Sensitivity Mode, and then the hub's transmit power
will be reduced.
The function is only available when the version of the DMSS app is 1.97
or later, and the hub is V1.001.0000000.6.R.211215 or later.
Set the server-hub ping interval with the range from 150 to 900 seconds
(150 seconds by default). If the D-cloud detects that the hub's offline
duration exceeds 150 seconds, it will report the hub status to the user
through app.
The function is only available when the version of the DMSS app is 1.96
or later, and the hub is V1.001.0000000.6.R.211215 or later.