Watchguard ALMKIT-D1 User Manual page 12

Alarm hub
Hide thumbs Also See for ALMKIT-D1:
Table of Contents

Advertisement

ATE
Reporting
Category
Time
DP3
3 min
DP4
90 s
ATE: Al-arm transmission equipment.
SPx (Single Path): A value that indicates the performance level achieved by a single
communication device, according to the EN 50136–1 standard.
DPx (Double Path): A value that indicates the performance level achieved by a combination of two
communication devices, according to the EN 50136–1 standard.
Reporting time: The reporting time is prescribed based on the standard of each level of
performance. Reporting time is the maximum time available to report when an alarm
transmission device fails. Al-arm transmission devices meet this requirement by regularly
reporting their status through a specific symbolic test function.
Protocols: Indicates the security level of the protocols to be used for the notification of failures.
Standard protocols and voice protocols are encrypted. High security protocols are encrypted with
an AES 128 bit or AES 256 bit encryption key.
Communication devices: Implemented communication devices.
Communication devices to be used: Indicates the number of and which communication devices
are to be used based on the ATE category.
Technical Specification
ACE Classification
Environmental Class
Supply Voltage
Product Dimensions
Packaging Dimensions
Operating Temperature
Humidity
Net Weight
Gross Weight
Casing
Protocols
Communication Devices
PSTN
Encrypted
Encrypted
Table 1-3 Technical specification
Description
Type A
II
12 VDC, 1.5 A
163.0 mm × 163.0 mm × 32.0 mm (6.42" × 6.42" × 1.26")
219.0 mm × 187.0 mm × 91.0 mm (8.62" × 7.36" × 3.58")
–10 °C to +50 °C (+14 °F to +122 °F)
–10 °C to +40 °C (+14 °F to 104 °F) (Certified temperature)
10%–90% (RH)
0.38 kg (0.84 lb)
0.8 kg (1.76 lb)
PC + ABS
5
Communication
Device to be Used
2G/3G
IP
The two check
marked
communication
devices
The two check
marked
communication
devices