Piranha4 RGB + NIR / Mono Camera User's Manual
Instructions on using the camera scan
direction to control camera parameters
The camera is capable of adjusting camera parameters on-the-fly based on the scan direction of the
camera. These parameters include gain, flat field coefficients, white balance and exposure time.
1. The first step is to put the camera in the reverse direction. This can be done using a reverse signal
through CC3 and the Direction Source set to external or by having the Direction Source set to
Internal and the Internal Direction set to reverse.
2. Set up all the desired parameters, including flat field corrections.
3. Save the camera parameters to a User set other than the default user set.
Teledyne DALSA
79
First, setup parameters for reverse
direction.
03-032-20217-02