Piranha4 RGB + NIR / Mono Camera User's Manual
Optional Lens Mount and Heat Sink Accessories
Description
M42 to F-mount adapter
M42 to C-mount adapter
Heat sink

Camera Mounting and Heat Sink Considerations

Up to two optional heat sinks can be installed on the camera. As illustrated, they are ideally positioned to
allow close spacing of the cameras. These heat sinks are designed to provide adequate convection cooling
when not obstructed by enclosures or mounting assemblies.
Teledyne DALSA recognises that each customer's application can be unique. In consideration, camera's
heat sinks have been designed in such a way that they can be repositioned on the different faces of the
camera or removed entirely, depending on the mounting configuration and its heat sinking potential.
Repositioning or removal of the heat sinks must be performed with care in order to avoid temperature
issues. The camera has the ability to measure its internal temperature. Use this feature to record the
internal temperature of the camera when it is mounted in your system and operating under the worst
case conditions. The camera will stop outputting data if its internal temperature reaches 80 °C.
Teledyne DALSA
Figure 11: Piranha4 Heat Sink Accessories Kit