[Pr.1010] Synchronous encoder axis start request: Link device type
Set link device type for use.
Other than below: Invalid
11H: RX (1 bit)
12H: RY (1 bit)
2
13H: RWr (1 bit)
14H: RWw (1 bit)
[Pr.1011] Synchronous encoder axis start request: Link device start No.
Set link device No. for use.
If the link device No. out of the range is set, the error "Outside link device start No. range" (error code: 1CC0H) occurs and the
synchronous encoder axis start via link device cannot be used.
[Pr.1012] Synchronous encoder axis start request: Link device bit specification
Set the bit No. that used in occasion when "13H: RWr (1 bit)" and "14H: RWw (1 bit)" had been set to "[Pr.1010] Link device
type".
Setting range: 00H to 0FH
If the value out of the range is set, the error "Outside the link device bit specification range" (error code: 1CC1H) occurs and
the synchronous encoder axis start via link device cannot be used.
[Pr.1013] Synchronous encoder axis start request: Link device logic setting
Set the logic for assignment signal.
(Valid for only 0th bit)
0: Negative logic
1: Positive logic
2 INPUT AXIS MODULE