• Restore operation at start of advanced synchronous control
Command position value [pulse]
Cam starting point is set to
"command position value = 0 [pulse]".
Cam reference position becomes
"0 - 200 = -200 [pulse]".
Cam axis position
value per cycle [pulse]
Cam axis length per cycle = 0 [pulse]
• Cam operation
Command position value [pulse]
0
-200
Cam axis position
value per cycle [pulse]
1000
0
The estimated cam pattern for
"Cam axis position value per cycle = 0 [pulse]" as the origin is determined.
0
1000
0
Cam operation starts from 0 point which is now
"Cam reference position = -200 [pulse]".