SERVICE PROGRAM MODE

4.2.11 NVRAM DATA DOWNLOAD

After doing the memory all clear procedure, NVRAM data will be reset to their
default settings. So it is necessary to upload the NVRAM data before clearing the
NVRAM, and to download the NVRAM data afterwards.
• SP5-824: Uploads from the BICU to a flash memory card.
• SP5-825: Downloads from a flash memory card to the BICU.

NVRAM Data Download (SP5-825)

NOTE: This procedure downloads all the settings stored in the NVRAM except for
the following items:
• Electrical total counter value (SP7-003)
• Machine serial number (SP5-811, SP5-920, SP5-925)
• Plug & Play brand name and production name setting (SP5-907)
• Some SBU settings (SP4-904-3, SP4-904-4, SP4-906, SP4-909)
[A]
1. Turn off the main switch.
2. Remove the application cover [A] (1 screw).
3. Plug the flash memory card [B] into the card slot.
NOTE: Make sure that the surface printed "A" faces the rear side of the
machine (as viewed from the front of the machine).
4. Turn on the main switch.
5. Access the SP mode 5-825.
6. The machine erases the current settings, then writes the new settings onto the
NVRAM on the BICU board. If downloading failed, an error message appears
(see "Program Download"). At this time, repeat the download procedure.
7. Turn off the main switch, then remove the IC card.
A265M514.WMF