TRANSFER UNIT
20 September 1999
6.4.2 IMAGE DENSITY SENSOR
[B]
[A]
A267R201.WMF
[D]
[C]
A267R202.WMF
1. Open the right cover [A].
2. Remove the unit band [B].
3. Remove the right cover [A] (1 connector),
4. Remove the sub right cover [C] (2 hooks).
5. Replace the image density sensor [D] (1 connector).
6. Reset the ID sensor error counter (SP 7-912).