20 September 1999
2.11.3 LOW POWER MODE
Entering the low power mode
The machine enters low power mode when:
• The low power shift timer runs out after the last job.
(User Tools - System Settings - Energy Saver Timer: default setting is 15 min)
What happens in low power mode
There are two low power modes; Low Power Mode Level 1 and Low Power Mode
Level 2. This can be selected by UP mode (User Tools - System Settings - Energy
Saver Level).
The fusing lamp drops to a certain temperature, as shown in the table below (the
temperature drops more than that in energy saver mode). The other conditions are
the same as for the energy saver mode.
The fusing temperature for the level 2 low power mode can be changed by SP 1-
105 (the default setting is 80 °C).
Return to stand-by mode
The machine returns to standby mode in the same way as from the energy saver
mode.
Operation
Mode
Switch
Low Power
Mode Level 1
Low Power
Mode Level 2
Energy
Saver
Fusing Temp.
LED
On
On
On
On
2-79
ENERGY SAVER MODES
Approx.
Recovery
Time
120 °C
15 s
80 °C
30 s
System
+5V
On
On