FUSING/EXIT
20 September 1999
6.5.5 PRESSURE ROLLER/CLEANING ROLLER
[A]
[B]
A267R507.WMF
1. Remove the fusing lamp and hot roller assembly. (See Hot Roller and Fusing
Lamp.)
2. Replace the pressure roller [A] (1 E-ring, 2 bushings, 1 spring).
3. Replace the cleaning roller [B].
NOTE: Do not touch the surface of the rollers.