Output Port Function; Line Source - Omron STC-MBS312U3V Product Specifications And User's Manual

Monochrome / color cmos camera
Table of Contents

Advertisement

8.2

Output Port Function

This function sets the Output to Line Mode, and then the Line is assigned as the output.
The following functions can be assigned when the IO port is used as the output signal port.
The following list shows the configurable functions available through the Line Source.
The function that describes as "Enable" on "Changeable Polarity" is the configurable polarity on the Line Inverter
(true, false).
No.
1)
2)
3)
4)
5)
6)
7)
8)
1) Off (Disable)
Disable the output signal.
2) User Output (General Output)
High or Low level signal that sets on the software is output.
3) Trigger Out (Trigger Output)
The trigger signal that added "Trigger Out Delay (Output pulse delay time)" and "Trigger Out On Time
(Output pulse width)" is output.
4) Exposure End Out (Exposure End)
"Trigger Out on Time (Output pulse width)" activation time signal with set "Trigger Out Delay (Output
pulse delay time)" is output when the expose was finished.
5) Frame End Out (Sensor Readout End)
"Trigger Out on Time (Output pulse width)" activation time signal with set "Trigger Out Delay (Output
pulse delay time)" is output when the sensor read out was finished.
6) Transfer End Out (Transfer End Output)
"Trigger Out on Time (Output pulse width)" activation time signal with set "Trigger Out Delay (Output
pulse delay time)" is output when one frame image transferring from camera was finished.
7) Strobe Out (Strobe Output)
"Strobe Out on Time (Output pulse width)" activation time signal with set "Strobe Out Delay (Strobe
output delay time)" is output when the trigger signal is received.
STC-MBS312U3V / STC-MCS312U3V / STC-MBS500U3V / STC-MCS500U3V
Product Specifications and Use's Guide
For more information please contact Aegis Electronic Group, Inc. *(888)687-6877 *aegis-g2@aegiselect.com *http://www.aegiselect.com
Function Name
Off (Default)
User Output
Trigger Out
Exposure End Out
Frame End Out
Transfer End Out
Strobe Out
Exposure Active
Changeable
Polarity
-
-
Enable
Enable
Enable
Enable
Enable
Enable
No.16S024-02