Service Manual
Adjustments

Pressure compensator Override (PCOR) setting

Series 51 Electrohydraulic Proportional Controls Service Manual
Locknut and Threshold
Locknut
10 mm
9 Nm [6.6 lbf•ft]

PCOR Adjustment

In order to measure and adjust the start pressure setting for the PCOR function:
1. Install a 600 bar [10000 psi] gauge at port M1 or M2 or M5 to read high system pressure.
2. Install a 600 bar [10000 psi] gauge at port M3 to read minimum servo pressure.
3. Lock the motor shaft from moving by:
Applying the park brake, apply an extreme load, or
Position the machine against an immovable object, or
Other means to hold the machine.
4. Start the prime mover. Operate at medium RPM.
5. Stroke the pump very slowly to gradually increase the system pressure.
11009448 • Rev BA • July 2014
Spring seat
P101 911
13