Danfoss AK-CC 550A Instructions Manual

Danfoss AK-CC 550A Instructions Manual

Hide thumbs Also See for AK-CC 550A:

Advertisement

Identification
084B8070
Principle
AKV info !!
AK-CC 550A - Standard
Additional information:
Weitere Information:
Renseignements supplémentarires:
Yderligere information:
Información adicional:
Informazioni aggiuntive!
Ytterligare information:
Aanvullende informatie:
RI8PR102
6-2012
Instructions
AK-CC 550A
084B8070
Dimensions
230 V a.c. spole
230 V a.c. coil
230 V a.c. Spule
230 V c.a. Bobine
230 V c.a. Bobina
230 V c.a. Bobine
English Manual
Deutsches Manual
Manuel en français
Dansk Manual
Manual español
Manuale in italiano
Svenska Handbok
Dutch Handleiding
S2:
Insulate sensor
Fühler isolieren
Capteur isolés
Isolér føleren
Sensores aislados
RS8FS...
www.danfoss.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AK-CC 550A and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Danfoss AK-CC 550A

  • Page 1 230 V a.c. spole 230 V a.c. coil 230 V a.c. Spule 230 V c.a. Bobine 230 V c.a. Bobina 230 V c.a. Bobine AK-CC 550A - Standard Additional information: English Manual Weitere Information: Deutsches Manual Renseignements supplémentarires: Manuel en français...
  • Page 2: Factory Setting

    Fra fabrikken er regulatoren leveret med skilte, der angiver anvendelse 2. Hvis du benytter en anden anvendelse, er der medleveret skilte, så du kan montere det aktuelle. Factory setting -> 1 - 8 Instructions RI8PR102 © Danfoss 6/2012 AK-CC 550A - 084B8070...
  • Page 3 AK-CC 550A - 084B8070 Instructions RI8PR102 © Danfoss 6/2012...
  • Page 4 Se litteratur: RC8AC AKA 245 version 6.20 + / System manager AK-SM..AK-SM... / Gateway Display EKA 163 / 164 L < 15 m L > 15 m Instructions RI8PR102 © Danfoss 6/2012 AK-CC 550A - 084B8070...
  • Page 5: Pressure Transmitter

    (the need for either S3 or S4 can be deselected in the configuration) Supply voltage S5, defrost sensor, placed on the evaporator 230 V a.c., 50/60 Hz S6, product sensor or defrost sensor B or air sensor B. The configuration determines which. AK-CC 550A - 084B8070 Instructions RI8PR102 © Danfoss 6/2012...
  • Page 6: Data Communication

    There is connection between terminal 12 and 14 when the hot Danfoss will not be responsible for any goods, or plant compo- gas valves must open. nents, damaged as a result of the above defects. It is the installer's responsibility to check the installation thoroughly, and to fit the necessary safety devices.
  • Page 7: Operation

    Find the parameter code you want to change and push the middle buttons until value for the parameter is shown. When you have changed the value, save the new value by once more pushing the middle button. AK-CC 550A - 084B8070 Instructions RI8PR102 © Danfoss 6/2012...
  • Page 8 - Send address to system unit: • MODBUS: Activate scan function in system unit • If another data communication card is used in the controller: - LON RS485: Activate the function o04 Instructions RI8PR102 © Danfoss 6/2012 AK-CC 550A - 084B8070...
  • Page 9: Menu Survey

    Defrost stop temperature 0°C 50°C Interval between defrost starts 0 hrs/Off 48 hrs Max. defrost duration 0 min. 360 min. Displacement of time on cutin of defrost at start-up 0 min. 240 min. AK-CC 550A - 084B8070 Instructions RI8PR102 © Danfoss 6/2012...
  • Page 10 Select signal for display view. S4% (100%=S4, 0%=S3) 100 % Pressure transmitter working range – min. value -1 bar 5 bar Pressure transmitter working range – max. value 6 bar 200 bar Instructions RI8PR102 © Danfoss 6/2012 AK-CC 550A - 084B8070...
  • Page 11 (E.g.: a value of 5 will activate all high temperature alarms and all sensor error. AK-CC 550A - 084B8070 Instructions RI8PR102 © Danfoss 6/2012...
  • Page 12 **) Can be controlled manually, but only when r12=-1 ***) With access code 2 the access to these menus will be limited Factory settings are indicated for standard units. Other code numbers have customized settings. Instructions RI8PR102 © Danfoss 6/2012 AK-CC 550A - 084B8070...
  • Page 13 The importance of individual alarms can be defined with a setting. The setting must be carried out in the group "Alarm destinations" Settings from Settings from Alarm relay Send via High Low-High System manager AKM (AKM destination) Network High Middle Log only Disabled AK-CC 550A - 084B8070 Instructions RI8PR102 © Danfoss 6/2012...
  • Page 14 Instructions RI8PR102 © Danfoss 6/2012 AK-CC 550A - 084B8070...

This manual is also suitable for:

084b8070

Table of Contents