Mitsubishi MELFA RH-6SH Series Standard Specifications Manual page 106

Table of Contents

Advertisement

3Controller
Note1)
Note1) The controller sucks in the outside air and discharges the inside air after cooling
The space required for cooling is 100 mm minimum. Reserve approximately 500 mm of space
behind the unit as the maintenance work area.
Fig.3-12 : Installation of controller(CR3-535M controller)
The controller has the openings (1) to (4) as shown in
Capcon installing panel
Cable lead in port
(1) Left surface input power supply
lead-in port
(2) Bottom surface input/output signal
lead-in port (with sponge)
(3) Left surface cable outlet
(4) Right surface input/output signal
lead-in port
(no sponge, with cabl fixing plate)
・Use (1) to lead in the input
power cable.
・Use (2) or (4) to lead in the
input/output signal cable.
Fig.3-13 : Cable lead-in ports and dimensions (CR3-535M controller)
Outside dimensions/Installation dimensions
3-94
Side
Approx.
200
450
Controller
(upside)
Maintenance area
(View from upside)
67
(1)
φ28
(3)
φ34
Left side drawing
<CR3-535M>
Side
Approx.
300
The mold cover
for the RS-232C connector
(Anchor bolt installation: 4 places)
Fig.
3-13.
STATUS NUMBER
CHANG DISP
EMG.STOP
UP
DOWN
MODE
SVO ON
START
RESET
TEACH
AUTO
AUTO
REMOVE T/B
(Op.)
(Ext.)
SVO OFF
STOP
END
Front drawing
273
(2)
□40×81
Bottom view
The rubber cover
for the T/B connector
(Fig.
(4)
□40×90
Right side drawing
Enlarged view of A section
(39)
90
3-7).