Placing The Gas Fire - Kalfire Gi75/59F Installation Instructions Manual

Table of Contents

Advertisement

The following action must be taken in order to
connect an existing flue duct:
1.
At the top of the flue duct, use a "renovation
set top with rain cap".
2.
Connect a flue liner or flexible flue liner to
this, fitted through the existing duct. Ensure
this is well sealed.
3.
Lead the flue liner or flexible flue liner
through the existing flue duct.
4.
Mount the "renovation set bottom concentric
- connection to flex" at the entrance to the
flue duct.
5.
Connect a flue liner or flexible flue liner to
this, fitted through the existing duct. Ensure
this is well sealed too.
6.
Check the flue ducts for any leaks.
CAREFUL!
Leaks can cause low pressure and prevent the
closed system from functioning properly.
7.
Seal any detected leakage.
5.2

Placing the gas fire

Place the rear wall taking the material into
account. See: Installation Instructions paragraph
2.3. Then place the gas fire at the desired
location. Mount the legs and finish the rear wall
as indicated in the following paragraphs.
5.2.1
Fitting and mounting the gas fire
The gas fire is placed on four adjustable support
legs. The support legs on the glass side of the
gas fire need to be precisely sawn off before they
can be mounted.
When the bolts are mounted against the rear
wall, a space of a minimum of two cm is created
between the rear side of the appliance and the
rear wall.
WARNING!
It is no longer possible to adjust the glass once
the surround has been finished. Should the
mounting of a modified glass as a result of the
incorrect placement of the original glass be
required, this will fall outside of the factory
warranty.
Figure 5: Setting support legs
Carry out the following steps to set and assemble
the gas fire:
1.
Unscrew two bolts (A) from each support leg.
2.
To ensure that the support legs are on the
desired height, you might have to saw the
top off the support legs.
3.
If necessary, place the support legs in the
designated holder.
4.
Set the approximate height.
5.
Screw the two bolts (A) back on.
6.
Set the exact height of the gas fire by
adjusting the tightness of the bolts on each
leg (B). The range of adjustment is 3 cm.
7.
Set the gas fire to spirit level by tightening or
loosening the bolts on each support leg.
8.
Place the front glass in the appliance.
9.
Adjust the wall clamp, leaving a minimum of
2 cm between the gas fire and the wall.
10. Secure the gas fire to the wall using the
previously mounted clamps (optional).
Figure 6: Mounting gas fire to wall (optional)
16

Advertisement

Table of Contents
loading

Table of Contents