Three Safety Measures For The Gas Fire - Kalfire Gi75/59F Installation Instructions Manual

Table of Contents

Advertisement

IMPORTANT!
The gas fire needs a permanent power supply.
Interrupting the power supply can impact
safety precautions.
The risk of discolouration
CAREFUL!
After the convection system of the fireplace has
been heated, air particles, cigarette smoke,
candles and oil lamps can cause discolouration
of walls and ceilings. Ensure sufficient
ventilation in the room in which the fireplace is
installed.
2.6
Three safety measures for the gas
fire
The flame is detected due to electronic
ionization measurement. If the gas fire does
not detect a flame during the start-up phase,
the gas supply is interrupted for one minute. A
new ignition attempt follows automatically. To
interrupt automatic ignition attempts
immediately; Press the on/off button (max 2
sec.) to switch the fire off immediately.
A 24-hour security system
If no flame is detected after three automatic
ignition attempts (for gas types G20, G25), a
blocking occurs. For gas types G30 and G31,
this blocking occurs after one ignition attempt.
This lockout can be manually unlocked twice
with the remote control. If no flame is detected
after these two manual releases, a 24-hour
lock-out will follow. You can then not use the
gas fire for 24 hours.
Pressure relief device
The gas fire is equipped with an overpressure
safety device to minimise risks. Should an
explosive ignition occur, the top window will
open forward to reduce pressure.