Explanation and Applications of Relay Connector

Type
Pin #
Relay-
1
contact
2
3
Safety Contact
4
5
Safety Contact
6
7
Safety Contact
8
Gi ON
Gi OFF
Remarks:
Max. 230 V, 2A cos(ɸ1).
The Gi checks the status of this input; it must be
closed before the start of the ignition cycle and
during the operational status of the Gi. If it is opened,
the Gi is deactivated, and a fault error is generated,
putting the Gi in a lockout status. This is
automatically reset when the input is closed.
The Gi checks the status of this input; it must be
closed before the start of the ignition cycle and
during the operational status of the Gi. If it is opened,
the Gi is deactivated, and a fault error is generated,
putting the Gi in a lockout status. This is
automatically reset when the input is closed.
The Gi monitors the status of this input; it must be
closed before the start of the ignition cycle and
during the operational status of the Gi. If it is opened,
the Gi is deactivated, a fault error is generated, and
the Gi enters a lockout status. A manual RESET is
required.
Applications:
Turning on/off an external
fan, light, or gas supply.
Shut Down Switch, door
contact switch, extractor
hood, mechanical ventilation,
negative pressure sensor,
hotel switch
Shut Down Switch, door
contact switch, extractor
hood, mechanical ventilation,
negative pressure sensor,
hotel switch.
Carbon monoxide sensor,
leak detection sensor.