Download Print this page

Emerson Rosemount Wireless WT210 Quick Start Manual page 7

Corrosion transmitters
Hide thumbs Also See for Rosemount Wireless WT210:

Advertisement

October 2023
4–6-in. elbow
Use 10 A/F socket with 2–24 Nm torque wrench and 4 mm hex
key provided. Torque dome nuts to 10 Nm.
2. If pipe is to be installed on an NPS/DN straight pipe or NPS/DN
long radius elbow, it is recommended to cut strap prior to
installation. If the pipe is a non-standard size then size and cut
strap to length as per section
Total strap length provided is 1580 mm. Cut to the following
lengths based on pipe diameter.
Note
Even though the strap can be pre-cut before mounting to
match the asset diameter, there may be a need to adjust
strapping once mounted on the asset.
NPS
4
6
8
10
12
14
16
Quick Start Guide
a. M6 x 20 mm countersunk screw (already fitted to sensor
bed assembly)
b. M6 dome nut
c. M6 washer
d. M6 Nord lock washer
DN
100
150
200
250
300
350
400
Strap mount
installation, step 4.
Strap length
(mm)
410
560
710
875
1025
1115
1280
Quick Start Guide
Strap length
(in.)
16.14
22.05
27.95
32.09
40.35
43.90
50.39
7

Advertisement

loading