Download Print this page

Emerson Rosemount Wireless WT210 Quick Start Manual page 5

Corrosion transmitters
Hide thumbs Also See for Rosemount Wireless WT210:

Advertisement

October 2023
Two stainless steel safety lanyards
4 x M6 dome nuts, 4 x M6 washer and 4 x M6 x 18mm
countersunk screws (for use with NPS 4–6" pipe, see
installation)
2 x Spare M6 strap hold plate bolts (M6 x 14 hex head bolts and 2
x M6 nord locks
2.2 
Clamp identification
Part number, weight, country of origin, and read instructions symbol
are displayed on the product label.
Figure 2-2: Product markings
2.3 
Required equipment
The equipment for clamp installation is supplied in Rosemount
IK220 Installation Kit for Rosemount Wireless Permasense Corrosion
Transmitters.
Torque wrench, 3/8-in. drive (2–24 Nm range)
13 mm socket, 3/8-in. drive
10 mm socket, 3/8-in. drive
4 mm hex key
Loctite 8009 anti-seize compound
Tin snips
Strap mount holder (recommended)
Quick Start Guide
Quick Start Guide
Pre-
5

Advertisement

loading