CALIBRATION MENU

SETUP MENU

03

BATTERY STATUS

SELECT INTERFACE
12 • Wall Mount 2-Way RF Compact Color Touchpanel: STX-1700CW
Calibration Menu
Calibration of the touchscreen is required if the active touch area of a button does
not coincide with the button's image. Select the Touch Screen Calibration button to
display the CALIBRATION MENU, as shown to the left. The CALIBRATION
MENU offers the choice to initiate calibration with the Perform Calibration button
or return to the previous screen with the Return button. Choose an option by
touching the appropriate button.
If you need to calibrate the touchpanel, the screen displays the message "Touch
Upper Left" centered on the panel with a cross hair in the upper left corner. Touch
the cross hair to initiate calibration. Another message, "Touch Upper Right", appears
with a cross hair in the correct corner. Touch the cross hair. A final message, "Touch
Lower Right", appears with a cross hair in the correct corner. Touch the crosshair to
finish the calibration and return to the MAIN MENU.
NOTE: When touching each crosshair during calibration, be as accurate as possible.
Use the tip of a capped pen or the eraser end of a pencil.
Setup Menu
To obtain the SETUP MENU, shown to the left, press the Setup button from the
MAIN MENU. The SETUP MENU offers a series of buttons, which open additional
menus and screens that are detailed in subsequent paragraphs. After setup parameters
have been set, select the Return button to return to the MAIN MENU.
NOTE: For convenience, the current CRESNET ID setting is displayed in the lower
left corner.
NOTE: All touchpanel settings are automatically saved in non-volatile memory.
Battery Status
To access the Battery Status screen, shown to the left, press the Battery Status
button on the SETUP MENU.
This screen indicates the amount of charge (or life) remaining in the battery as a
percentage of full capacity, if the battery is installed. An analog bar is provided
below the percentage amount as a quick visual reference to the approximate level of
charge remaining. The EXTERNAL POWER label appears if external power is
applied either through the docking station or via the optional power pack. Note that
battery recharging takes place only through the docking station. Touch the Return
button to display the SETUP MENU.
NOTE: When charging the battery, the battery status screen is not an accurate
indicator of battery level. The battery status screen will indicate a full charge (100%)
before the docking station indicates that charging is complete (RDY illuminates).
Select Interface
The touchpanel communicates with a control system to activate commands or to
display feedback from components within the system. The communication interface
must be correctly specified or communication will not occur. To set communication
parameters, first select the Interface button on the SETUP MENU to display the
SELECT INTERFACE screen, shown to the left. Then, select either the CRESNET
or the RF button to display the CRESNET INTERFACE MENU or the RF SETUP
screen, respectively. Use these screens to set the Cresnet network identity
(CRESNET ID) and the RF ID numbers.