Transmission Characteristics - Mitel 3300 ICP Hardware Technical Reference Manual

For mivoice business
Hide thumbs Also See for 3300 ICP:
Table of Contents

Advertisement

C
5
HAPTER
Time-Out Information (Continued) (Sheet 2 of 2)
Table 5.1:
Feature
Camp-On Recall Timer
Call Hold Timer
Attendant Busyout Timer
First Digit Timer
Interdigit Timer
Delay Ring Timer
Callback Cancel Timer
Call Forward - No Answer
Timer
Switchhook Flash
Ringing Timer

Transmission Characteristics

The transmission characteristics of all country variants of the 3300 ICP and ancillary subsystems comply
with the specifications listed in
Time-Out Period
0 - 180 s
10 - 600 s
1 - 1440 min
5 - 60 s
3 - 60 s
5 - 60 s
1 - 24 hrs
0 - 125 s
60 - 1500 ms
60 - 300 s
Table 53, "Supported Transmission Standards," on page
T
RANSMISSION
A
A : S
, T
PPENDIX
IGNALING
Description
Incoming calls camp-on to a
busy station before being
returned to the attendant, if not
answered before time-out
expires.
Calls placed on hold ring back
to the station user upon expiry.
System switches to night
service if there is no activity at
the attendant console after calls
are received.
This is the time the system will
wait for the first digit after going
off-hook at a station.
Time between dialed digits.
Time before line rings on key
set.
Time after which callback
functions are reset and cleared
or cancelled.
Length of time a station rings
before the call is forwarded or
rerouted.
Length of time that a
switch-hook can be flashed
without dropping the trunk or
line.
The length of time a station
rings another station before the
call is terminated.
C
HARACTERISTICS
,
T
ONES
AND
RANSMISSION
77.
70

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

3300 mxe iii-l3300 mxe iii3300 ax3300 cx3300 cxi3300 cx ii ... Show all

Table of Contents