C
4
HAPTER
Specifications
Environment
Controller
Storage Environment
Table 4.1:
Condition
Temperature
Humidity
Vibration
Mechanical Stress
Operational Environment
Table 4.2:
Condition
Temperature
Humidity
Maximum Heat Dissipation - fully loaded (see
Note)
Air Flow
Acoustic Emissions
: Conversion factors: 1 watt is equal to 3.412 BTUs per hour, 1 ton of refrigeration is equal to 12,000
NOTE
BTUs per hour or 3.516 Kilowatts, and 3/4 Kilowatt-hour is equal to 1 ton of refrigeration.
Specification
-40º to 150ºF (-40º to +66ºC)
15-95% Relative Humidity, non-condensing
0.5 g, 5 to 100 Hz, any orthogonal axis
1.5 g, 100 to 500 Hz, any orthogonal axis
One 6 in. (15.3 cm) drop, each edge and corner
adjacent to the rest face – unpackaged
One 30 in. (76.2 cm) drop, each edge and corner
packaged in cardboard & foam.
Specification
40º to 122º F (4º to 50º C)
5-95% Relative Humidity, non condensing
500 BTUs per hour (100-user)
750 BTUs per hour (250/700-user, MXe Base)
850 BTUs per hours (MXe Expanded)
170 BTUs per hour
1020 BTUs per hour (CXi II)
1020 BTUs per hour (AX)
46 cubic feet per minute at maximum output of
the fans
110 cubic feet per minute at maximum output (AX
only)
Maximum 50 dBA continuous, 75 dB intermittent
(<10% duty cycle)
E
NVIRONMENT
S
PECIFICATIONS
61