Specifications; Dual T1/E1 Framer; Description - Mitel 3300 ICP Hardware Technical Reference Manual

For mivoice business
Hide thumbs Also See for 3300 ICP:
Table of Contents

Advertisement

C
2
HAPTER

Specifications

The CIM ports require standard 8-pin modular jacks (RJ-45) consisting of 2 balanced signal pairs on Cate-
gory 5 Unshielded Twisted Pair (UTP) crossover cable.
The CIM supports a distance of up to 100 feet or 30 meters between cabinets.

Dual T1/E1 Framer

Description

The Dual T1/E1 Framer MMC is a digital trunk interface that supports the direct connection of ISDN-PRI,
T1/D4, QSIG, and MSDN/DPNSS trunks to the controller.
This module has two ports, each supporting a digital link. LEDs on the faceplate indicate the status of
each link. For a description of LED status and alarm indications, refer to the 3300 ICP Technician's
Handbook .
Each of these links can be configured as a T1 (1.544 Mbps) (North America) or E1 (2.048 Mbps) (Europe)
interface.
T1 features:
Support for ISDN PRI, QSIG, and T1/D4 links
B8ZS or AMI line coding
Superframe (SF) or Extended Superframe (EXF) framing
E1 features:
Support for ISDN PRI and QSIG links
CRC4 enable or disable
: The following ISDN PRI features are not supported: D-channel backup, NFAS, min/max capability,
NOTE
and TDM XNET (Hybrid XNET is supported).
The Dual T1/E1 Framer module requires a 300 MHz or faster processor.
The Dual T1/E1 Framer MMC is a Field Replaceable Unit (FRU) that can be installed in any of the MMC
sites in the front panel of the 3300 controller.
: The module is not designed for hot insertion into an MMC module site on a powered-up carrier card.
NOTE
Refer to the 3300 ICP Technician's Handbook for installation procedures.
F
U
R
IELD
PGRADEABLE AND
Dual T1/E1 Framer
Figure 2.11:
C
EPLACEABLE
ONTROLLER
M
(AX, MX
, CX
II)
ODULES
E
I
3300 ICP C
ONTROLLERS
20

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

3300 mxe iii-l3300 mxe iii3300 ax3300 cx3300 cxi3300 cx ii ... Show all

Table of Contents