Paging (Universal ASU only)
The paging interface provides two paging ports.
Each paging port is a transformer-coupled interface providing:
600 ohm input impedance
•
Full duplex capability
•
A complete 2/4 wire hybrid interface
•
A balance impedance set at 600 ohms.
•
The two overhead paging outputs, in combination with their relay contacts, support two paging zones.
ASU Paging Zones vs. Audio Circuit Numbers and Relay Positions
Table 3.3:
ASU Paging Zone Number
1
2
3
4
0
Paging is accomplished by one of two methods:
Zone control via outpulsed DTMF digits
•
E&M trunk emulation using contact-closure control.
•
The Paging Connector Pin Allocation is shown in the following table.