C
2
HAPTER
ONS Cards
16 On-Premise Station (ONS) Lines for analog phones
•
24 On-Premise Station (ONS) Lines for analog phones
•
Protected ONS ports (ONSP) are available on the
4 + 12 Port Combo card (can be used on the ASU II and the AX).
•
24 port and 16 port ONS card (can be used on the ASU II and the AX).
•
The ONSP ports are suitable for off-premise applications and meet the requirements of 60950-01 and IEC
55024. Regular ONS ports are intended for on-premise applications only.
ONS lines connect to the module using a 25-pair female D-type (Amphenol) connector.
ONSP ports use the same loss plan settings as regular ONS ports. You require a TDM license to enable
each port.
Both the 4 + 12 Port Combo cards and ONS cards are hot-swappable.
LS CLASS
The AX and ASU II support Custom Local Access Signaling Services (CLASS) on the LS trunks and ONS
lines. CLASS allows the 3300 ICP system to pass Calling Line ID digits and CLASS name information to
display sets that support Caller ID functionality. The ASU II also supports ETSI signalling. The signalling
type is set in the System Administration Tool.
AX/ASU II Specifications
ONS/ONSP
ONS / ONSp Station Line Circuits (Sheet 1 of 2)
Table 2.14:
Attribute
2
Battery Reversal
Constant Current
DC Leakage Resistance Immunity
Dial Pulse Detection
External Loop Drive Capability (Ringing Range)
Earth Recall detection
Ground Button detection
Ground Start detection
Loop Current Limit
Loop Feed Type
Loop status LED
F
U
R
IELD
PGRADEABLE AND
AX/ASU II line cards
All regions
25 mA
10 kΩ
No
1
1200
No
No
No
25 mA (up to 1600 Ω, including DC resistance of
set)
constant
per card
C
EPLACEABLE
ONTROLLER
Ωfor 2 REN, 900 Ωfor 3 REN
M
(AX, MX
, CX
II)
ODULES
E
I
3300 ICP C
ONTROLLERS
26