C
6
HAPTER
Appendix B : Ethernet Cabling Guidelines
Introduction
The 3300 ICP system transmits voice communications over a data network using Voice over Internet
Protocol (VoIP). Electrical interference in the environment can reduce the quality of the voice and data
signals that are transmitted over Ethernet cable. Desktop computers, printers, servers, lighting, and other
office devices place a high demand on the electrical infrastructure and increase the risk of electrical inter-
ference. You can minimize electrical interference and improve network efficiency by following the cabling
guidelines detailed in this appendix.
: Special testing equipment is available from Mitel Product Support. This equipment can verify
NOTE
Ethernet cable performance and detect cable faults.
Maximum Cable Lengths
Maximum CAT 5 or CAT 5e Ethernet Cable Lengt hs
Table 6.1:
Cabling
Under Desk
Floor to ceiling
Horizontal span in ceiling
Equipment closet
Total maximum length
Cabling Guidelines for the Desktop
Refer to Figure 34 and the corresponding cabling guidelines to minimize electrical interference at the
desktop.
Maximum Length
10 ft. (3 m)
11.5 ft. (3.5 m)
300 ft. (90 m)
11.5 ft. (3.5 m)
333 ft. (100 m)
Desktop Cabling
Figure 6.1: