View Charge Tracking Data with QuiQ Programmer
CT
Requirement: To view the charge tracking data in your charger,
your charger must have version 3.X software. Note that only
chargers with serial number beginning with "DQCM" may
have version 3.X software programmed in it.
Start Application in User Mode
• Click on the Charge Event Database tab. This will display
the Charger Summary Dialog for that summarizes charge
data for the connected charger.
3121634
SECTION 3 - CHASSIS & TURNTABLE

Selecting a Charge Profile

Delta-Q's QuiQ Charger can store up to 10 charging profiles,
also called charge algorithms. This section shows how to iden-
tify the default profile and select a new profile using the "tap
method."
QuiQ chargers are reprogrammable using the QuiQ Program-
mer supplied by Delta-Q to its OEM partners. Pre-2006 QuiQ
chargers with serial number prefix DQCP allow pre-loaded
profiles to be selected, but cannot be reprogrammed with
new profiles.
IDENTIFY THE DEFAULT PROFILE
1. Required supplies include an insulated wrench, eye pro-
tection and gloves.
2. Disconnect the AC power source from the charger,
either from the wall outlet, or from the IEC320 connector
on the charger.
3. Disconnect power from the batteries using the battery
disconnect on the side of the machine.
4. Reconnect AC power.
5. For 11 seconds after the self-test, the charger will display
its default charge profile. Profiles are indicated by the
number of consecutive flashes followed by a pause
(e.g. #2 =
5b. Charge profiles in the double digits will display in the
same way, by one or more flashes, a pause, then one or
more flashes
(e.g. #42 =
6. After 11 seconds the red fault light will then blink.
).
)