SECTION 5 - BASIC HYDRAULIC INFORMATION & HYDRAULIC SCHEMATICS
5-80
TO PORT "P1"
(HELAC)
PORT "R2"
TO PORT "P2"
(HELAC)
PORT "R1"
NOTE: Solenoid Valves are torqued 19-21 ft.lbs. (25.8-28.6 Nm).
NOTE: Solenoid Coils are rated at 8.8 Ohms.
ROTATE
Figure 5-38. Fly Boom Control Valve Identification
PORT "P "
TO PORT "P2"
(VALVE, UPRIGHT)
Coils are torqued 4-5 ft.lbs. (5.4-6.8 Nm).
JIB
PORT "MP"
TO PORT "V2"
(JIB LIFT CYL)
PORT "J2"
TO PORT "V1"
(JIB LIFT CYL)
PORT "J1"
MAE15750D
3121634