NEC Express5800 Series Maintenance Manual page 165

Hide thumbs Also See for Express5800 Series:
Table of Contents

Advertisement

Chapter 3 Appendix
Error Message
C120
BMC Runtime FW corrupted.
BMC Force Update FW corrupted. Failed to start BMC FW.
C121
C122
BMC Configuration area
corrupted.
C123
BMC eMMC inaccessible.
C125
BMC eMMC mode error.
BMC eMMC partition corrupted. An error occurred on partition of
C126
C127
BMC eMMC format corrupted.
C128
BMC is in Update Mode.
C200 The error occurred during memory
configuration check.
C300
Out-of-band setup
configuration failure
C301
SDR mismatch error.
Hardware configuration error. Detected that hardware
C302
C310
Hardware configuration of
cooling is insufficient.
C320
Unmatched PSUs.
C321
System power consumption is
out-of-range in PSUs.
C322
No information for system
power consumption check.
C400
Can't Read FRU on CPU Unit
TypeI Mezzanine
C401
Can't Read FRU on CPU Unit
TypeII Mezzanine
C501
ME is in Recovery Mode.
Cause
Failed to start BMC FW.
An error occurred on BMC
Configuration area.
Initialization failed due to an access
error occurred in internal flash
memory of BMC.
A mode error occurred in internal
flash memory of BMC.
internal flash memory of BMC.
A format error occurred in internal
flash memory of BMC.
BMC is in firmware update mode.
Memory configuration check error
was detected.
An error was detected while
accessing BMC Mezzanine card.
Inconsistency in the hardware
information of the sensor data
record was detected.
configuration of the server is illegal.
Detected that cooling power is
insufficient in this hardware
configuration.
Detected that unmatched power
supply units are configured.
Detected that system power
consumption exceeds the power
output capacity limit.
Detected that no information was
acquired in checking system power
consumption.
Cannot read Mezzanine Slot1 FRU.
Cannot read Mezzanine Slot2 FRU.
Intel Node Manager is in Recovery
Mode.
Express5800/B120f-h Maintenance Guide
1. Error Message of POST and Virtual LCD
Solution
Power off the CPU blade, remove it from
blade enclosure, wait for at least 30
seconds, and then install it again.
Contact your sales representative.
Power off the CPU blade, remove it from
blade enclosure, wait for at least 30
seconds, and then install it again.
Contact your sales representative.
Turn off the power, wait for at least 30
seconds, check the power supply units, and
restart the server.
Contact your sales representative.
Power off the CPU blade, remove it from
blade enclosure, wait for at least 30
seconds, and then install it again.
165

Advertisement

Table of Contents
loading

This manual is also suitable for:

Express5800/b120f-h exp437a

Table of Contents