NEC Express5800 Series Maintenance Manual page 162

Hide thumbs Also See for Express5800 Series:
Table of Contents

Advertisement

Chapter 3 Appendix
Error Message
Expansion ROM not initialized There is no free area for expanding
B000
B030
PCI System Error on
Bus/Device/Function
B040
PCI Parity Error on
Bus/Device/Function
Onboard VGA - PCIe Link Failure Connection failure of PCIe bus was
B200
B201
Onboard LAN 1 – PCIe Link
Failure
B202
Onboard LAN 2 - PCIe Link
Failure
B220
Onboard VGA - PCIe Link Width
Error
B221
Onboard LAN 1 – PCIe Link
Width Error
B222
Onboard LAN 2 – PCIe Link
Width Error
B260
Onboard VGA - PCIe Link Speed
Error
B261
Onboard LAN 1 – PCIe Link
Speed Error
B262
Onboard LAN 2 – PCIe Link
Speed Error
B2A1
Mezzanine Slot 1 - PCIE Link
Speed Error
B2A2
Mezzanine Slot 2 - PCIE Link
Speed Error
B2A3
Mezzanine Slot 3 - PCIE Link
Speed Error
B2A4
Mezzanine Slot 4 - PCIE Link
Speed Error
B2A8
PCI Slot - PCIE Link Speed
Error
B2AA
I/O Blade PCI Slot - PCIE Link
Speed Error
B301
Expansion ROM not initialized
- Mezzanine Slot 1
B302
Expansion ROM not initialized
- Mezzanine Slot 2
B303
Expansion ROM not initialized
- Mezzanine Slot 3
B304
Expansion ROM not initialized
- Mezzanine Slot 4
B30A
Expansion ROM not initialized
- I/O Blade PCI Slot
B330
Expansion ROM not initialized
- PCI Slot
162
Cause
option ROM.
PCI SERR was detected.
PCI PERR was detected.
detected on onboard VGA.
Connection failure of PCIe bus was
detected on onboard LAN1
Connection failure of PCIe bus was
detected on onboard LAN2
Link Width error was detected on
onboard VGA.
Link Width error was detected on
onboard LAN1.
Link Width error was detected on
onboard LAN2.
Link Speed error was detected on
onboard VGA.
Link Speed error was detected on
onboard LAN1.
Link Speed error was detected on
onboard LAN2.
Link Speed error was detected on
Mezzanine Slot 1.
Link Speed error was detected on
Mezzanine Slot 2.
Link Speed error was detected on
Mezzanine Slot 3.
Link Speed error was detected on
Mezzanine Slot 4.
Link Speed error was detected on
PCI Slot PCIE.
Link Speed error was detected on
I/O Blade PCI Slot.
Failed to expand option ROM of
Mezzanine slot 1.
Failed to expand option ROM of
Mezzanine slot 2.
Failed to expand option ROM of
Mezzanine slot 3.
Failed to expand option ROM of
Mezzanine slot 4.
Failed to expand option ROM of I/O
Blade PCI slot.
Failed to expand option ROM of PCI
Slot.
Express5800/B120f-h Maintenance Guide
1. Error Message of POST and Virtual LCD
Solution
If the device is not used as a boot device,
disable Option ROM Scan for that device.
Contact your sales representative.
Contact your sales representative.
Disable the expansion of option ROM for
the device that is not used as a boot
device.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Express5800/b120f-h exp437a

Table of Contents