2.4.3 PROFIdrive State Machine

In the PROFIdrive control profile, the control bits perform different functions:
0–3 perform the basic start-up and power-down functions.
4–10 perform application-oriented control.
12–15 can be configured for different purposes.
See
Illustration 1
for the basic state transition diagram, where control bits 0–3 control the transitions and the corresponding status
bit indicates the actual state. The black dots indicate the priority of the control signals. Fewer dots indicate lower priority, and more
dots indicate higher priority.
The general state diagram is defined in the PROFIdrive standard.
Danfoss A/S © 2023.09
Description
0 = Quick stop activated (OFF3).
1 = Switching on inhibited.
0 = Switching on not inhibited.
1 = A warning has occurred.
0 = There are no warnings.
1 = The present motor speed matches the present speed reference within a given tolerance.
The tolerance is product specific.
0 = The motor runs, but the present speed is different from the present speed reference. It
could, for example, be the case while the speed ramps up/down during start/stop.
1 = The device is controlled and reacting to I/O and process data.
0 = The device does not react to commands from the fieldbus for 1 of the following reasons:
CTW bit 10 = 0.
HMI is in local mode.
MyDrive® Insight has taken control.
Control places do not include fieldbus.
1 = The output frequency is within the defined motor limits.
0 = The output frequency has exceeded the defined motor limits given by parameters.
The speed limits are set by parameters:
P 5.8.3.4 High Speed Warning
P 5.8.3.9 Low Speed Monitor Limit
These bits enable mapping application functionality of the drive to the status word. Mapping
is done through parameters. For more information, refer to the Parameter Descriptions chap-
ter in the application guide.