Class Id 0Xf6 Link Object - Danfoss EtherNet/IP iC7 Series Operating Manual

Hide thumbs Also See for EtherNet/IP iC7 Series:
Table of Contents

Advertisement

iC7 Series EtherNet/IP
Operating Guide
Attrib-
Access
Name
ute
8
Get/Set
TTL value
9
Get/Set
Multicast config
Num Mcast
Multicast start address
10
Get/Set
Select ACD
11
Get
Last conflict detected
ACD activity
Remote MAC
ArpPdu
13
Get/Set
Encap. inactivity time-
out

6.1.8 Class ID 0xF6 Link Object

3 instances of the link object are implemented:
Instance 1 relates to the internal interface of the option after the built-in switch.
Instance 2 relates to fieldbus port X1.
Instance 3 relates to fieldbus port X2.
Table 29: Instance Attributes for Class ID 0xF6 Link Object
Attrib-
Access
Name
ute
1
Get
Interface speed
2
Get
Interface flags
3
Get
Physical address
4
Get
Interface counters
In octets
In Ucast packets
In NUcast packets
In discards
In errors
In unknown protos
38 | Danfoss A/S © 2023.09
Datatype
Description
USINT
Time-to-Live value for IP multicast packets. Default value is 1.
Struct of:
UINT
Number of IP multicast addresses to allocate for EtherNet/IP.
UDINT
Starting multicast address from which to begin allocation, A
block of Num Mcast addresses is allocated starting with this
address.
BOOL
Enable ACD:
0 = Disabled (default)
1 = Enabled
Struct of:
USINT
State of ACD activity when last conflict detected
Array of 6
MAC address of remote node from the ARP PDU in which a
USINT
conflict was detected.
Array of 28
Copy of the raw ARP PDU in which a conflict was detected.
USINT
Number of seconds of inactivity before TCP connection is
closed
Datatype
Description
UDINT
Interface speed in Mbps
DWORD
Interface status flags
ARRAY of 6 USINTs
MAC layer address
Struct of:
UDINT
Octets received on the interface
UDINT
Unicast packets received on the interface
UDINT
Non-unicast packets received on the interface
UDINT
Inbound packets received on the interface but discarded.
UDINT
Inbound packets that contain errors (does not include In Dis-
cards)
UDINT
Inbound packets with unknown protocol
EtherNet/IP Features
AQ456329199699en-000101 / 136R0335

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ic7-automationIc7-baipEthernet/ip os7ip

Table of Contents