10.

JUMPERS

EVERTZ (A) 7700PB2
MODULE STATUS
SIGNAL PRESENT
AUDIO Run
J16
Upgrade
FRAME
STATUS
ON
OFF
J22
10.1. SELECTING WHETHER LOCAL FAULTS WILL BE MONITORED
BY THE GLOBAL FRAME STATUS
FRAME STATUS: The FRAME STATUS jumper J22 located at the front of the module determines
whether local faults (as shown by the Local Fault indicator) will be connected to the
7700FR frame's global status bus.
To monitor faults on this module with the frame status indicators (on the PS FRAME
STATUS LED's and on the Frame's Fault Tally output) install this jumper (Default).
When this jumper is removed, local faults on this module will not be monitored. For
convenience the user may re-install the jumper so that only one side is connected.
The Frame stat trigger menu item on the GPO configuration menu is used to configure
whether Fault condition 1 or Fault condition 2 will assert the frame status fault line.
Power supply faults will always assert the frame status fault line when J22 is installed.
7735AVC-LB Video Composite Encoder and Audio DAC with SoftSwitch
J8
SFF POWER
GND
+12V

Figure 10-1: Location of Jumpers on 7700PB2 Boards