Njoy Garun 30KL User Manual

3 phase in / 3 phase out ups
Hide thumbs Also See for Garun 30KL:

Advertisement

Quick Links

Garun Series
30KL / 40KL
3 Phase IN / 3 Phase OUT UPS
UP33TOP130KGAAZ01B
User Manual
UP33TOP140KGAAZ01B
Before using this product, carefully read all product documentation and retain it for future reference.
940.34.21.0

Advertisement

Table of Contents
loading

Summary of Contents for Njoy Garun 30KL

  • Page 1 Garun Series 30KL / 40KL 3 Phase IN / 3 Phase OUT UPS UP33TOP130KGAAZ01B User Manual UP33TOP140KGAAZ01B Before using this product, carefully read all product documentation and retain it for future reference. 940.34.21.0...
  • Page 2: Table Of Contents

    1-4. Connection warnings ....................6 1-5. Operation ........................7 Focusing on quality at competitive prices, here at nJoy, we are creating innovative and reliable power 1-6. Standards ........................7 protection solutions for every customer in casual, 2. Installation and operation ..................8 business and industrial environments.
  • Page 3: Safety And Emc Instructions

    Safety and EMC instructions All safety instructions in this document must be read, understood and followed. 1.1. Transportation and storage WARNING • Please transport the UPS system only in the original packaging to protect against shock and damage. Please comply with all warnings and operating instructions in this manual. •...
  • Page 4: Connection Warnings

    1.4. Connection warnings Before working on this circuit 1. Isolate Uninterruptible Power Supply (UPS) • There is no standard backfeed protection inside of the UPS. However, 2. Then check for Hazardous Voltage between all terminals including the there are relays on the Input to cut off line voltage while the neutral is still protected earth.
  • Page 5: Installation And Operation

    NOTE! Installation and operation Before the installation, please inspect the unit. Be sure that there is no physical damage to the unit. Do not turn on the unit and notify the carrier and dealer immediately if there is any damage or missing parts and accessories. Please keep 2.1.
  • Page 6: Ups Positioning

    Diagram 1: Garun 30KL/40KL Rear panel Caution! It’s NOT allow to have flammable, explosive or corrosive gas or liquid in installation environment. It is forbidden to install in a metal conductive dust Diagram 2: Garun 30KL, 40KL Dual Input / Output terminal environment.
  • Page 7: Single Ups Installation

    140A IMPORTANT! • The cables for Garun 30KL should be able to withstand over 50A current • Make sure a DC breaker or other protective device between UPS and the for Input and Output phase, 85A for Neutral, 105A for battery cabinet and external battery pack is installed.
  • Page 8: Ups Installation For Parallel System

    ON/OFF UPS Battery test Control Electrical Mute all ON/OFF charger Battery Miscellaneous Wiring diagram of parallel system for Garun 30KL, 40KL Measure 1 User mode Check section 3.5. for Parallel operation of UPS. Password: 0000 Measure Measure 2 Measure 3 2.6.
  • Page 9: 3-2.1. Main Screen

    NOTE! 3.2.2. Control screen Maintainer Menu is detailed only in ‘Addendum to User manual’. If you need Touch the icon to enter control sub-menu. assistance or have any warning or fault codes on your UPS screen, please contact the technician that installed the UPS. DO NOT attempt to modify any settings of the UPS unless you are a trained technician.
  • Page 10: 3-2.3. Measure Screen

    Battery test ON/OFF Charger It will show “Battery Test” if the UPS is not in test. Touch “Yes” to start It will show “Turn on Charger?” when charger is off. battery test. Then, it will show “Battery testing..…” during battery test period. It will show “Turn off Charger?”...
  • Page 11: 3-2.4. Setting Screen

    OUTPUT VOL: The real time value of R, S and T output voltage, RS, ST and 3.2.4. Setting screen TR voltage and frequency This sub-menu is used to set the parameters of UPS. Touch the icon to enter setting menu page. There are 2 options: Basic and Advanced. Touch the icon to return to main screen.
  • Page 12 General Audio Alarm: There are two events available to mute. You may choose “Enable” or “Disable” alarm when related events occur. Enable: When selected, alarm will be mute when related events occur. Disable: When selected, UPS will alarm when related events occur. All Mute: When “enable”...
  • Page 13 Disable: CVCF function is disabled. The output frequency will synchronize with the bypass frequency within 46~54 Hz for 50Hz system or within 56~64 Hz for 60Hz system. Disable is the default setting. Bypass Forbid: Enable: Bypass forbid is enabled. When selected, it’s not allowed for running in Bypass mode under any situations.
  • Page 14 H: High voltage point for ECO mode. The setting range is from “Rated • MISCELLANEOUS output voltage + 5V” to “Rated output voltage + 11V”. “Rated output voltage + 5V” is default setting. ECO FREE Range: Set the ECO frequency range. The setting range is from 46Hz to 54Hz when the UPS is 50Hz system and from 56Hz to 64Hz when the UPS is 60Hz system.
  • Page 15: 3-2.5. Information Screen

    3.2.5. Information screen Touch the icon to enter information page. Touch the icon browse information. Touch the icon to return to main screen. Touch the icon to go back to previous menu. • BASIC information Basic Information Page2 PAR State: The information of parallel state. PAR ID: The UPS ID number in parallel state.
  • Page 16: 3-2.6. Data Log Screen

    • PARAMETER information Shutdown Voltage: If battery voltage is lower this point, UPS will automatically shut down. Battery Age: It shows battery age. Battery AH: It shows battery AH Battery Number: It shows battery number. Parameter Information Page1 Line Voltage Range: The acceptable line input voltage range. Line FRE Range: The acceptable line input frequency range.
  • Page 17: Audible Alarm

    3.4. Single UPS operation WARNING This UPS should be started by authorized personal only. Please contact technician that installed the UPS if you need to perform additional tasks on UPS. 3.4.1. Turn on the UPS with utility power (in AC mode) •...
  • Page 18 • If the UPS is overload, the buzzer will beep twice every second. 3.4.6. Test the batteries • If the UPS is overloaded, please remove some loads immediately. It is • If you need to check the battery status when the UPS is running in AC recommended to have the total loads connected to the UPS less than 80% of mode/CVCF mode, you could touch “CONTROL”...
  • Page 19: Parallel Operation

    3.4.11. Operation in Fault mode • Connect each UPS one by one with the data cable and share current cable, as shown in below picture: • When Fault LED illuminates and the buzzer beeps continuously, it means that there is a fatal error with the UPS. Users can get the fault code from “DATA LOG”...
  • Page 20: Fault Code

    • Turn on the parallel system in Battery mode: d) Turn on the input breaker of the remaining UPS and the system will a) Turn on the battery breaker and output breaker of each UPS. transfer to Bypass mode. Set the maintenance switches from “BPS” b) Turn on any UPS.
  • Page 21: Warning Code

    3.7. Warning Code Inverter C-A output (line Bypass O/P short to line) short circuited circuited Warning Warning Bypass O/P line to line Warning event Warning event Inverter A negative code code short power fault circuited Line situations are different in Battery unconnected parallel system Inverter B negative...
  • Page 22: Troubleshooting

    Problem Possible cause Solutions Troubleshooting The UPS shut Fault code is down automatically Check output wiring and if If the UPS system does not operate correctly, please solve the problem by shown as 14, because short circuit connected devices are in short using the table below.
  • Page 23: Storage And Maintenance

    • Batteries may cause electric shock and have a high short-circuit current. Storage and maintenance Please remove all wristwatches, rings and other metal person objects before maintenance or repair, and only use tools with insulated grips and handles for 5.1. Storage maintaining or repairing.
  • Page 24 Memo Disposal of Old Electrical & Electronic Equipment (Applicable in the European Union and other European countries with separate collection systems) This symbol on the product or on its packaging indicates that this product shall not be treated as household waste. Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment.