Overlapped Finishing Clearances
Figure 4.12 120 VAC Overlapped Finishing Clearances
240VAC Overlapped Finishing Area
When using 240VAC input, all overlapped finishing mate-
rial, behind the decorative front, in the non-combustible
zone must be a non-combustible material only.
Non-Combustible
Figure 4.13 240 VAC Overlapped Finishing Clearances
18
120VAC Overlapped Combustible Finishing Material
36-1/8 in.
240VAC Non-Combustible Zone
240VAC Overlapped Combustible Finishing Material
1-1/8 in.
(28 mm)
32-5/8 in.
(829 mm)
SimpliFire • SF-INC36 Owner's - Installation Manual • 4200-900 Rev D • 8/23
918 mm
36-1/8 in.
918 mm
1-3/8 in.
(34 mm)
Max.
32-5/8 in.
829 mm
Combustible
1/4 in.
(6 mm)
Max.
Combustible
34 in.
(864 mm)