Video Intercom Face Recognition Door Station User Manual
2. Check to enable elevator control function.
3. Select an Elevator No., and select an elevator controller type for the elevator.
4. Set the Negative Floor.
5. Select the Interface Type as RS-485 or Network Interface. And enable the elevator control.
- If you select RS-485, make sure you have connected the door station to the elevator controller
with RS-485 wire.
- If you select Network interface, enter the elevator controller's IP address, port No., user
name, and password.
6. Click Save to enable the settings.
Note
Up to 4 elevator controllers can be connected to one door station.
●
Up to 10 negative floors can be added.
●
Make sure the interface types of elevator controllers, which are connected to the same door
●
station are consistent.
RS-485 Settings
Set the working mode to linked device.
Steps
1. Click Access Control → RS-485 to enter the settings page.
Figure 7-16 Elevator Control
43