Wexiodisk WD-11 touch Installation And User Manual page 55

Tunnel dishwasher
Hide thumbs Also See for WD-11 touch:
Table of Contents

Advertisement

Technical specifications
CONNECTION, ELECTRICALLY HEATED MACHINE
Total connected load (kW)
Main fuse 400-415 V 3N~ (A) *
Max. connection area 400V 3N~ (L1-L3, N, PE) Cu (mm²)
Main fuse 400-440 V 3~ (A) *
Max. connection area 400-440 V 3~ (L1-L3, PE) Cu (mm²)
Main fuse 230 V 3~ (A) *
Max. connection area 230 V 3~ (L1-L3, PE) Cu (mm²)
* Other voltages on request
** Option
WATER, DRAIN AND VENTILATION CONNECTIONS
Water quality, hardness (° dH)
Water connection 5-70° C (internal thread)
Waste pipe connection, PP pipe (ø mm)
Hot water capacity, pressure (kPa) **
Water capacity, hot water, flow (litres/minute)
Floor drain, capacity (litres/sec.)
Ventilation requirement (m³/h)
Ventilation connection, infeed ø125mm (m³/h)
Ventilation connection, outfeed ø160mm (m³/h)
Heat load to room, latent / sensible / total (kW)
* option
** At lower pressures, the machine should be supplemented with a break tank
SIZE AND WEIGHT FOR TRANSPORT *
Size, LxWxH (m) **
Weight (kg) **
* Normal delivery fully assembled. If necessary, delivered in smaller components.
** Including packaging
WD-11
touch
51
Rev. 00 (202310)
19.7
35 / 50 **/ 63**
25
35 / 50 **
25
63 / 100 **
25
2–7
R½"
50
250–600
11
3
1200
400
1200
3.0 / 4.5 / 7.5
2.1 x 0.8 x 2.0
280

Advertisement

Table of Contents
loading

Table of Contents