Ventilation; Steam (Optional); Drain/Waste Pipe - Wexiodisk WD-153 optiflow Installation And User Manual

Tunnel dishwasher
Table of Contents

Advertisement

Installation instructions

3.5.3 Ventilation

The machine's heat load for the room is stipulated in TECHNICAL SPECIFICA-
TIONS.
The machine has a heat recovery unit connected to an exhaust fan to reduce the
amount of steam released. Extractor fans for extracting steam can be installed
above the infeed and outfeed openings, as well as above the area of the machine
where steam is emitted from the condensing fan.
If a hood is fitted over the machine, it much be positioned so that it covers the dry-
ing rack after the machine and preferably also the exhaust from the condensing
fan.

3.5.4 Steam (optional)

Condensing water
A condensation connection (6) is only provided on steam-heated machines. The
pipe is connected to the system's steam boiler.

3.5.5 Drain/waste pipe

The waste water system connected to (4 or 12) should consist of a 50mm metal
pipe that will withstand mechanical impacts. The waste pipe must run to a floor
drain, where its opening must be above the water level.
The drain can be fitted to the right or left. Remove the perforated section of the
end plate and pull the pipe through the hole. Connect the drain and run to the floor
drain where it should flow freely above the water level.
Ensure that the drain connection is kept in place by using e.g. cable ties in the
designated areas.
WD-153 - WD-423
A shut-off cock must be installed on the incoming pipe. The required steam
pressure can be found in the TECHNICAL SPECIFICATIONS.
If the machine is steam-heated, connect the pipes for steam at (5).
23
optiflow
Rev. 00 (202310)

Advertisement

Table of Contents
loading

Table of Contents