Download Print this page

Mitsubishi Electric FR-A820-04750-GF Instruction Manual page 74

Hide thumbs Also See for FR-A820-04750-GF:

Advertisement

Pr.
Name
Frequency command
541
0, 1

sign selection
USB communication
547
0 to 31
station number
USB communication
0 to 999.8s,
548
check time interval
9999
549
Protocol selection
0, 1
NET mode operation
550
command source
0, 1, 9999
selection
PU mode operation
551
command source
1 to 3, 9999
selection
552
Frequency jump range 0 to 30Hz, 9999
553
PID deviation limit
0 to 100%, 9999 9999
PID signal operation
554
0 to 3, 10 to 13
selection
555
Current average time
0.1 to 1.0s
556
Data output mask time 0 to 20s
Current average value
0 to 500A
557
monitor signal output
0 to 3600A
reference current
Second frequency
0 to 32767,
560
search gain
9999
PTC thermistor
0.5 to 30kΩ,
561
protection level
9999
Energization time
563
(0 to 65535)
carrying-over times
Operating time
564
(0 to 65535)
carrying-over times
Second motor
0 to 400Hz,
565
excitation current break
9999
point
Second motor
566
excitation current low-
0 to 300%, 9999 9999
speed scaling factor
Second motor speed
569
0 to 200%, 9999 9999
control gain
570
Multiple rating setting
0 to 3
571
Holding time at a start
0 to 10s, 9999
4 mA input check
1 to 4, 11 to 14,
573
selection
21 to 24, 9999
Second motor online
574
0 to 2
auto tuning
Output interruption
0 to 3600s,
575
detection time
9999
Output interruption
576
0 to 590Hz
detection level
Output interruption
577
900 to 1100%
cancel level
Traverse function
592
0 to 2
selection
Maximum amplitude
593
0 to 25%
amount
Amplitude
594
compensation amount
0 to 50%
during deceleration
Amplitude
595
compensation amount
0 to 50%
during acceleration
Amplitude acceleration
596
0.1 to 3600s
time
Amplitude deceleration
597
0.1 to 3600s
time
175 to 215V/
598
Undervoltage level
350 to 430V
9999
X10 terminal input
599
0, 1
selection
First free thermal
0 to 590Hz,
600
reduction frequency 1
9999
First free thermal
601
1 to 100%
reduction ratio 1
First free thermal
0 to 590Hz,
602
reduction frequency 2
9999
First free thermal
603
1 to 100%
reduction ratio 2
First free thermal
0 to 590Hz,
604
reduction frequency 3
9999
Power failure stop
606
external signal input
0, 1
selection
Motor permissible load
607
110 to 250%
level
Second motor
110 to 250%,
608
permissible load level
9999
PID set point/deviation
609
1 to 5
input selection
PID measured value
610
1 to 5
input selection
Acceleration time at a
0 to 3600s,
611
restart
9999
Reverse rotation
617
excitation current low-
0 to 300%, 9999 9999
speed scaling factor
Cumulative pulse clear
635
0 to 3

signal selection
16
PARAMETER LIST
Setting
Initial
Pr.
range
value
Cumulative pulse
0
636

division scaling factor
Control terminal option-
0
637
Cumulative pulse

division scaling factor
9999
Cumulative pulse
638

storage
0
Brake opening current
639
selection
9999
Brake operation
640
frequency selection
9999
Second brake
641
sequence operation
selection
9999
Second brake opening
642
frequency
0
Second brake opening
643
current
1s
Second brake opening
644
0s
current detection time
Inverter

Second brake operation
645
rated
time at start

current
Second brake operation
646
frequency
9999
Second brake operation
647
time at stop
9999
Second deceleration
648
detection function
0
selection
Second brake opening
0
650
current selection
Second brake operation
651
9999
frequency selection
Speed smoothing
653
control
Speed smoothing cutoff
654
frequency
Analog remote output
655
selection
2
656
Analog remote output 1
9999
657
Analog remote output 2
9999
658
Analog remote output 3
659
Analog remote output 4
0
Increased magnetic
660
excitation deceleration
1s
operation selection
Magnetic excitation
661
0Hz
increase rate
Increased magnetic
662
excitation current level 0 to 300%
1000%
Control circuit
0
663
temperature signal
output level
10%
Regeneration
665
avoidance frequency
gain
10%
Power failure stop
668
frequency gain
SF-PR slip amount
10%
673
adjustment operation
selection
5s
SF-PR slip amount
674
adjustment gain
5s
User parameter auto
675
storage function
selection
,
9999

679
Second droop gain
Second droop filter time
680
0
constant
Second droop function
681
9999
activation selection
Second droop break
682
100%
point gain
Second droop break
683
9999
point torque
Tuning data unit
684
100%
switchover
686
Maintenance timer 2
9999
Maintenance timer 2
687
warning output set time 0 to 9998, 9999 9999
1
688
Maintenance timer 3
Maintenance timer 3
689
warning output set time 0 to 9998, 9999 9999
150%
690
Deceleration check time
9999
Second free thermal
692
reduction frequency 1
2
Second free thermal
693
reduction ratio 1
3
Second free thermal
694
reduction frequency 2
9999
Second free thermal
695
reduction ratio 2
Second free thermal
696
reduction frequency 3
699
Input terminal filter
0
Maximum motor
702
frequency
Setting
Initial
Name
range
value
1 to 16384
1
1 to 16384
1
0 to 3
0
0, 1
0
0, 1
0
0, 7, 8, 9999
0
0 to 30Hz
3Hz
0 to 400%
130%
0 to 2s
0.3s
0 to 5s
0.3s
0 to 30Hz
6Hz
0 to 5s
0.3s
0, 1
0
0, 1
0
0, 1
0
0 to 200%
0
0 to 120Hz
20Hz
0, 1, 10, 11
0
1000%
1000%
800 to 1200%
1000%
1000%
0, 1
0
0 to 40%, 9999 9999
100%
0 to 100°C
0°C
0 to 200%
100%
0 to 200%
100%
2, 4, 6, 9999
9999
0 to 500%
100%
1, 9999
9999
0 to 100%, 9999 9999
0 to 1s, 9999
9999
0 to 2, 10, 11, 
9999
20 to 22, 9999
0.1 to 100%,
9999
9999
0.1 to 100%,
9999
9999
0, 1
0
0 (1 to 9998)
0
0 (1 to 9998)
0
0 to 3600s,
1s
9999
0 to 590Hz,
9999
9999
1 to 100%
100%
0 to 590Hz,
9999
9999
1 to 100%
100%
0 to 590Hz,
9999
9999
5 to 50ms, 9999 9999
0 to 400Hz,
9999
9999
Setting
Pr.
Name
range
Induced voltage
0 to 5000mV/
706
constant (phi f)
(rad/s), 9999
707
Motor inertia (integer)
10 to 999, 9999 9999
711
Motor Ld decay ratio
0 to 100%, 9999 9999
712
Motor Lq decay ratio
0 to 100%, 9999 9999
Starting resistance
717
0 to 200%, 9999 9999
tuning compensation
0 to 6000μs, 
Starting magnetic pole
721
position detection pulse
10000 to
width
16000μs, 9999
724
Motor inertia (exponent) 0 to 7, 9999
Motor protection current
100 to 500%,
725
level
9999
Second motor induced
0 to 5000mV/
738
voltage constant (phi f)
(rad/s), 9999
Second motor Ld decay
739
0 to 100%, 9999 9999
ratio
Second motor Lq decay
740
0 to 100%, 9999 9999
ratio
Second starting
741
resistance tuning
0 to 200%, 9999 9999
compensation
0 to 6000μs, 
Second motor magnetic
742
pole detection pulse
10000 to
width
16000μs, 9999
Second motor
0 to 400Hz,
743
maximum frequency
9999
Second motor inertia
744
10 to 999, 9999 9999
(integer)
Second motor inertia
745
0 to 7, 9999
(exponent)
Second motor
746
100 to 500%, 9999 9999
protection current level
Second motor low-
747
speed range torque
0, 9999
characteristic selection
0, 10, 11, 20, 21,
50, 51, 60, 61,
70, 71, 80, 81,
90, 91, 100,
Second PID action
753
101, 1000,
selection
1001, 1010,
1011, 2000,
2001, 2010,
2011
Second PID control
0 to 590Hz,
754
automatic switchover
9999
frequency
Second PID action set
755
0 to 100%, 9999 9999
point
Second PID
0.1 to 1000%,
756
proportional band
9999
Second PID integral
0.1 to 3600s,
757
time
9999
Second PID differential
0.01 to 10.00s,
758
time
9999
759
PID unit selection
0 to 43, 9999
Pre-charge fault
760
0, 1
selection
761
Pre-charge ending level 0 to 100%, 9999 9999
0 to 3600s,
762
Pre-charge ending time
9999
Pre-charge upper
763
0 to 100%, 9999 9999
detection level
0 to 3600s,
764
Pre-charge time limit
9999
Second pre-charge
765
0, 1
fault selection
Second pre-charge
766
0 to 100%, 9999 9999
ending level
Second pre-charge
0 to 3600s,
767
ending time
9999
Second pre-charge
768
0 to 100%, 9999 9999
upper detection level
Second pre-charge
769
0 to 3600s, 9999
time limit
Operation panel
1 to 3, 5 to 14, 
774
monitor selection 1
17 to 20, 22 to 36,
Operation panel
38 to 46, 50 to 57,
775
61, 62, 64, 67, 
monitor selection 2
71 to 75, 87 to 98,
Operation panel
776
100, 9999
monitor selection 3
4 mA input check
777
0 to 590Hz, 9999
operation frequency
778
4 mA input check filter
0 to 10s
Operation frequency
779
during communication
0 to 590Hz, 9999

error
Low speed range
788
torque characteristic
0, 9999
selection
Acceleration time in
791
0 to 3600s, 9999
low-speed range
Deceleration time in
792
0 to 3600s, 9999
low-speed range
Pulse increment setting
0.1, 1, 10,
799
for output power
100, 1000kWh
Initial
value
9999
9999
9999
9999
9999
9999
9999
9999
9999
0
9999
100%
1s
9999
9999
0
9999
9999
0
9999
9999
9999
9999
9999
9999
0s
9999
9999
9999
9999
1kWh

Advertisement

loading