A.2 - Temporarily deactivating (and reactivating) motors you do not wish to program
A
NOTES AND WARNINGS
• This procedure, which is useful for programming the limit switches of multiple channels without switching the motors off, temporarily locks out (for 5 minutes) only the
motors that have both the limit switch positions (up and down) already programmed.
A.2.1 - To temporarily deactivate motors you do not wish to program
1
= 5 sec
ESC
Hold down the but-
release it after 5 sec-
ton and
onds;
A.2.2 - To reactivate temporarily locked out motors
You can reactivate the motors in two ways:
1
After 5 minutes the
locked out motors are
automatically reactivat-
ed by the system.
Wait for 5 minutes ...
A.3 - MANUAL programming of the UP ("0") and DOWN ("1") limit switches
A
NOTES AND WARNINGS
• This procedure is obligatory only for awnings without a mechanical stop at the Up position.
• After the limit positions have been programmed, the awning can be controlled by simply pressing the appropriate buttons on the control unit. The awning will move
between the positions set with procedures A.3.1 and A.3.2.
A.3.1 - To program the UP limit switch ("0")
1
(x 1)
PRG
Press and re-
count 2 movements.
lease the button (1
time);
 3
" 0 "
... release the button as soon as the awning
reaches position "0" ( UP limit switch).
7 – English
ESC
you will see a brief down
movement and a movement
which stops the awning at
the Up limit "0".
end
... the system will then
move the awning to
the mid position.
2
= 5 sec
2
release it after 5
Hold down the but-
ton and
seconds;
4
Finely adjust-
ing the posi-
tion of limit
switch "0"
Press the buttons until you reach the desired position.
2
The system locks out only those motors whose lim-
" 0 "
it switches have already been programmed. It has
no effect on motors which have not yet been pro-
grammed.
The deactivation is temporary and lasts for 5
minutes.
For a period of 5 minutes, the locked out motors will
not respond to commands.
1
During the 5 minute
period the locked out
motors can be reacti-
vated at any time by the
user.
During the 5 minutes, at
... hold down the
any time...
button and
2
count 2 movements.
" 0 "
end
= 10 sec
ESC
ESC
release it after 10
seconds;
3
Command
an UP
movement
Hold down the button and wait...
5
= 5 sec
Hold down the
release it after 5
button and
seconds;
end
the system will then
move the awning to
the mid position.
continues
end
3
count 3 movements.