Nice E EDGE SI 228 LI ION Instructions And Warnings For Installation And Use page 13

Tubular motor

Advertisement

5
= 5 sec
Hold down both buttons...
A.7.2 - Procedure run with a transmitter which has not yet been memorised
NOTES AND WARNINGS
• In order to carry out the following procedures, a transmitter with a PRG button should be used.
A.7.2.A - Procedure run with a non-memorised transmitter using the button on the head of the motor
1
= 7 sec
On the motor head: press and hold
the button;
A.8 - Adjusting the motor's sensitivity to obstacles
A
NOTES AND WARNINGS
• Use this procedure to activate, adjust or deactivate the safety system that: a) detects the presence of an obstacle along the travel of the awning; b) reduces the mo-
tor tension on the awning when it is stationary at the Upper limit switch "0" (only if there is a box or other mechanical stop at this limit switch).
• This procedure adjusts the limit of the traction force that the motor can exert on the awning in an attempt to release it, when it is stopped suddenly by an obstacle
or friction. At the same time, if the Upper limit switch "0" is the box or other mechanical stop, the system uses the same value set with this procedure, to reduce the
impact of the awning against the box and loosen the tension exerted by the motor on the canvas, when the awning is stationary at the Upper limit switch "0".
• The following options are available:
– MINIMUM sensitivity(*) – this setting is only active when the awning is moving Up. The motor delivers a lot of force and will often be able to unjam the awning,
even when the load is varying due to friction or small obstacles.
– ULTRA sensitivity(*) – this setting is active when the awning is moving Down.
– ULTRA sensitivity(*) with brief inversion – this setting is active when the awning is moving Up or Down. If an obstacle is detected when the awning is moving
Down, the motor briefly inverts the movement to free it.
– ULTRA sensitivity(*) with full inversion – this setting is active when the awning is moving Up or Down. If an obstacle is detected when the awning is moving Up,
the motor inverts the movement and stops the awning at the Lowest point "1".
– sensitivity DISABLED – this setting disables the safety system (factory setting).
1
(x 1)
2
PRG
Press and release
count 2 movements.
the button (1 time);
4
(x ...)
Select the de-
sired option and
program it as fol-
lows
Press and release the button the number of times indicated in the option you have chosen;
release them after 5
count 5 movements.
seconds;
release it after 7 seconds;
2
(x 1)
PRG
Press and release
count 2 movements.
the button (1 time);
5 OPTIONS:
1 press = sets MINIMUM sensitivity
2 presses = sets ULTRA sensitivity
3 presses = sets ULTRA sensitivity with short reverse
4 presses = sets ULTRA sensitivity, with reverse
5 presses = sets DISABLED sensitivity
end
5
the red led starts flashing (it turns off when the procedure is
completed).
3
= 5 sec
2
Hold down both buttons...
when the light starts
flashing, you have 1
minutes to complete
the procedure.
release them after 5
count 2 movements.
seconds;
continues
2
...
Run procedure
A.7.1 in full.
 4
2