Download Print this page

Nice E EDGE SI 228 LI ION Instructions And Warnings For Installation And Use page 16

Tubular motor

Advertisement

 5
1 /
2 /
3 /
7
4 /
sec.
5 /
After about 7 seconds, the motor performs a num-
ber of movements equal to the number of pulses
entered.
A.11 - Adjusting the total duration of the movement
A
NOTES AND WARNINGS
• This adjustment can only be done if the limit switches ("0" and "1") have already been programmed.
• The value set with this procedure, together with the "acceleration/deceleration" setting (procedure A.10) determines the cruise speed. To determine whether the re-
sulting cruise speed is compatible with the awning (weight, roller dimensions, torque), refer to "Technical characteristics".
• The factory setting is disabled.
1
(x 1)
PRG
Press and release
count 2 movements.
the button (1 time);
4
Select the desired op-
tion and program it as
follows
 4
1 /
2 /
3 /
7
4 /
sec.
5 /
After about 7 seconds, the motor performs a num-
ber of movements equal to the number of pulses
entered.
15 – English
6
= 5 sec
?
Hold down the button;
2
(x 1)
2
PRG
Press and release
the button (1 time);
5 OPTIONS:
(x ...)
1 press = sets 7 seconds
2 presses = sets 15 seconds
3 presses = sets 20 seconds
4 presses = sets 30 seconds
5 presses = deactivates the function and sets nominal speed
Press and release the button the number of times indicated in the option you have chosen;
5
= 5 sec
?
Hold down the button;
release it after 5 seconds;
3
= 5 sec
2
count 2 movements.
Hold down the button;
release it after 5 seconds;
end
3
count 3 movements.
release it after 5
count 3 movements.
seconds;
continues
end
3
count 3 movements.
 4
3

Advertisement

loading