Ariston COMPACT M NET R32 Technical Instructions For Installation page 73

Table of Contents

Advertisement

Menu.
Sub-menu.
Parameter
13.
9
HP diagnostics - input 2
13.
9.
0 Heat Pump Mode
13.
9.
1 Last inverter error
13.
9.
2 HP evaporator refrigerant flow temp. (TEIM)
13.
9.
3 Flowmeter
13.
9.
4 Boiler Flowswitch
13.
9.
5 Inverter shut off protection
13.
9.
6 Evaporator pressure P
13.
9.
7 Condenser pressure P
13. 10
HP diagnostics - output 1
13. 10.
0 Inverter Capacity
13. 10.
1 HP actual compressor frequency
13. 10.
2 HP set compressor modulation
13. 10.
3 Electric Heater 1
13. 10.
4 CH Circulator status
13. 10.
5 Measured rpm fan 1
13. 10.
6 Measured rpm fan 2
13. 10.
7 Expansion valve
13. 11
HP diagnostics - output 2
13. 11.
0 compressor on/off
13. 11.
1 compressor preheating
13. 11.
2 current fan 1 status
13. 11.
3 current fan 2 status
13. 11.
4 4way valve heat / cool
13. 11.
5 Base panel heater status
13. 12
Service
13. 12.
0 SW Version main
Description
Default
Range - Value
0 = OFF
1 = Standby
2 = Cool mode
3 = CH
4 = Booster Heating
5 = Booster Cooling
6 = Rating Heating Mode
7 = Rating Cooling Mode
8 = Frost Protection
9 = Defrost
10 = High temperature pro-
tection
11 = Timeguard
12 = System Fail
13 = System Fail
14 = Pump Down
15 = Soft Fail Mode
16 = Rating only fan
17 = Defrost
18 = Casacade heating
19 = Cascade cooling
0 = Open
1 = Close
0 = Open
1 = Close
0 = OFF
1 = ON
0 = OFF
1 = ON
0 = OFF
1 = ON
0 = OFF
1 = ON
0 = OFF
1 = ON
0 = OFF
1 = ON
0 = CH
1 = Cool mode
0 = OFF
1 = ON
Commissioning
Notes
73 / EN