Standard Sg Ready - Ariston COMPACT M NET R32 Technical Instructions For Installation

Table of Contents

Advertisement

Under-floor system
°C
23
22
21
20
19
1
18
17
16
15
14
8
14
19
1
Delivery temperature to the system
2
Outside air temperature
When the outdoor temperature rises (summer), three condi-
tions may arise:
– The room temperature increases, indicating that a gen-
tler curve must be set.
– The room temperature decreases, indicating that a
steeper curve must be set.
– The temperature of the room remains constant, indicat-
ing that the set curve is exactly right.
Once you have found the curve which maintains the room
temperature at a constant level, check the actual temperature
value.
IMPORTANT:
If the room temperature is higher than the desired value,
the curve must be shifted lower. If the room temperature
is too low, the curve should be shifted upwards. If the
temperature of the room corresponds with the desired
value, the curve is correct.
In the above graph, the curves have been divided into
two groups:
– Fan-coil systems
– Under-floor systems
60 / EN
30
25
20
15
10
5
0
24
29
34
39
44 °C
2
Fig. 103
4.5.4 Parallel shifting
Turn the selector
then set the most suitable value and
press the selector
to confirm.
4.5.6 Maximum delivery temperature
Turn the selector
then set the most suitable value and
press the selector
to confirm.
4.5.7 Minimum delivery temperature
Repeat the steps described previously to set the values for
zone 2 (where present), by selecting menu 5.
6.8

Standard SG ready

The SG ready function is activated from the technical menu Par.
1.1.0 (=3) and Par. 1.1.4 (=3).
SG
SG
Ready 1
Ready 2
Input
Input
0 V
0 V
The system works according to its
230 V
0 V
The system is OFF for maximum 2
hours, the anti-freeze protection
0 V
230 V
mode during the reduced time slot
the delivery set-point is set to the
230 V
230 V
mode during the reduced time slot
the delivery set-point is set to the
comfort set-point temperature. The
heating elements are not enabled.
Commissioning
Description
standard logics.
remains active.
In the schedule programming
comfort set-point temperature.
In the schedule programming

Advertisement

Table of Contents
loading

This manual is also suitable for:

3301721330172233017233301724